5ST63-R

BEL FUSE Inc.
Type 5ST / 5STP Time-lag Fuse Series (Low Breaking Capacity) 5ST/5STP Series, 5x20mm Glass Tube Time-lag Fuse RoHS 2 Compliant Description 5x20mm Time-lag, low breaking capacity, glass tube body cartridge fuse designed, approved and complied with IEC 60127-2,standard sheet 3. Features - Meet IEC standard 60127-2, sheet 3 - Wide operating temperature range - Bulk and Tape & Reel packing a...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Номинальный ток
Напряжение AC
Класс быстродействия
Отключающая способность AC
Особенности Electric Fuse, Time Lag Blow, 0.063A, 250VAC, 35A (IR), Inline/holder, 5x20mm
Размер ø5.1×20 мм
Рабочая температура
Одобрение
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
Type 5ST / 5STP Time-lag Fuse Series (Low Breaking Capacity) 5ST/5STP Series, 5x20mm Glass Tube Time-lag Fuse RoHS 2 Compliant Description 5x20mm Time-lag, low breaking capacity, glass tube body cartridge fuse designed, approved and complied with IEC 60127-2,standard sheet 3. Features - Meet IEC standard 60127-2, sheet 3 - Wide operating temperature range - Bulk and Tape & Reel packing available - RoHS 2 compliant - Halogen Free - Lead Free Applications Provide individual protection for components or internal circuits. - Power supplies - Battery charger - Monitor LEAD FREE = - Adapter HALOGEN FREE = Physical Specifications Body : Glass Materials Cap : Nickel Plated Brass Caps Leads : Matte Tin Plated Copper On Fuse : “bel”, ”T”, ”Current Rating”, “L”,”250V”, ”Appropriate Safety Logos”, ”  ”( RoHS 2 compliant) Marking On Label : "bel", "5ST”or”5STP", "Current Rating", "Voltage Rating", "Interrupting Rating", "Appropriate Safety Logos" and " Electrical Characteristics (IEC-127-2 STANDARD SHEET 3) 1.5 In 2.1 In 2.75 In 4 In 10 In Rated Current MIN MAX MIN MAX MIN MAX MIN MAX Safety Agency Safety Agency Certificate 1 2 200 10 40 3 10 300 15133392 125mA to12.5A 1 2 600 10 150 3 20 300 40000507 hr. min. ms sec ms sec ms ms E20624 6.3A is 63VDC. "(China RoHS compliant). Safety Agency Approvals 63mA to100mA In clause 9.2, the test voltage for 5STP ratings from 63mA to ", " LR39772 2003010207030316 Voltage Rating (V) Ampere Range / Volt @ I.R. ability* 63mA-6.3A/250V AC@35A or 10 In whichever is greater 63mA-10A 63mA-10A/250V AC@35A /250V AC or 10 In whichever is greater 63mA-6.3A/250V AC@35A or 10 In whichever is greater *I.R.= Interrupting Rating = Short Circuit Rating(Amps) Specifications subject to change without notice belfuse.com/circuit-protection PDF
Документация на 5ST63-R 

Microsoft Word - 5ST Jan2019

Дата модификации: 06.03.2019

Размер: 786.2 Кб

4 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.