9505SMA

Розетка с винтовыми клеммами (с зажимной клетью) для реле 40.51, 40.52, 40.61, 44.52, 44.62; применяются модули 99.02, 86.03; в комплекте металлическая клипса 095.71; версия: синий цвет
развернуть ▼ свернуть ▲

Файлы 1

показать свернуть
44 Series - Miniature PCB relays 6 - 10 A Features 44.52 44.62 2 Pole relay range 44.52 - 2 Pole 6 A (5 mm pin pitch) 44.62 - 2 Pole 10 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets High physical separation between adjacent contacts • DC coils (Standard or sensitive) • Cadmium Free contact materials • 8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts • UL Listing (certain relay/socket combinations) • Flux proof: RT II • 95 series sockets • Coil EMC suppression • Timer accessories 86 series • 2 Pole, 6 A 5 mm contact pin pitch • PCB or 95 series sockets 2 Pole, 10 A 5 mm contact pin pitch • PCB or 95 series sockets • • • • 12.4 25 29 1 5 0.4 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE “General technical information” page V Copper side view Copper side view 2 CO (DPDT) 2 CO (DPDT) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC 6/10 10/20 250/400 250/400 Rated load AC1 VA 1,500 2,500 Rated load AC15 (230 V AC) VA 250 500 Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material 0.185 0.37 6/0.3/0.13 10/0.3/0.13 300 (5/5) 300 (5/5) AgNi AgNi — — Coil specification Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power AC/DC/sens. DC VA (50 Hz)/W/W Operating range AC 6 - 9 - 12 - 14 - 24 - 28 - 48 - 60 - 110 - 125 —/0.65/0.5 —/0.65/0.5 — — DC/sens. DC (0.73…1.5)UN/(0.73…1.7)UN (0.73…1.5)UN/(0.8…1.7)UN Holding voltage AC/DC —/0.4 UN —/0.4 UN Must drop-out voltage AC/DC —/0.1 UN —/0.1 UN Mechanical life AC/DC cycles —/20 · 106 —/20 · 106 Electrical life at rated load AC1 cycles 150 · 103 100 · 103 8/5 - (12/5 sensitive) 8/5 - (12/5 sensitive) 6 (8 mm) 6 (8 mm) 1,000 1,000 –40…+85 –40…+85 RT II RT II Technical data Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kV Dielectric strength between open contacts Ambient temperature range Environmental protection V AC °C Approvals (according to type) 1 PDF
Документация на 9505SPA 

Дата модификации: 20.02.2009

Размер: 999.7 Кб

12 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.