REDIN480-24/3AC

• • • • • • • Features DIN-Rail Series 2 and 3-phase operation Input voltage range: 320 – 575VAC Output trim range: 22.5 – 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel operation capability International safety certification listing Description The REDIN/3AC is a series of rugged DIN rail power supplies for two and three-phase mai...
развернуть ▼ свернуть ▲
 

Файлы 1

показать свернуть
• • • • • • • Features DIN-Rail Series 2 and 3-phase operation Input voltage range: 320 – 575VAC Output trim range: 22.5 – 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel operation capability International safety certification listing Description The REDIN/3AC is a series of rugged DIN rail power supplies for two and three-phase mains operation from 320 to 575VAC without the need of a neutral connection. Four versions with a maximum current limited output deliver 5A, 10A, 20A or 40A without derating up to +55°C. The output can be grounded via a third common output terminal. The LED signal on the front panel indicates that the output voltage remains within the wide adjustable range from 22.5 to 29.5VDC. The units are covered by international safety certificates and are intended for worldwide use. In power-hungry applications, the units can be connected in parallel with no need for additional components. AC/DC Converter REDIN480/3AC 480 Watt 3 Phase DIN-Rail Power Supply Selection Guide Part Number nom. Input Voltage Range [VAC] REDIN480-24/3AC 400-500 Output Voltage [VDC] 24 Output Adjustability [VDC] 22.5-29.5 Rated Current [A] 20 Efficiency (1) typ. [%] 91 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Model Numbering REDIN480-__/3AC nom. Output Power Output Voltage Specifications (measured @ Ta= 25°C, nom.Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Input Voltage Range E196683 Condition Min. Typ. Max. 3 phase operation 2 phase operation 320VAC 360VAC 400VAC 400VAC 575VAC 575VAC 3 phase operation 400VAC 500VAC 3 x 1100mA 3 x 800mA 2 phase operation 400VAC 500VAC 2 x 700mA 2 x 600mA Input Current Inrush Current 15A Powerfactor Return Voltage Immunity 0.67 24 Vout 6W AC Input Output Voltage Trimming Minimum Load Start-up time 45Hz 65Hz 22.5VDC 29.5VDC 0% 2/3 phase operation, 400VAC 1s Rise time Hold-up time Output Ripple & Noise UL60950-1 certified UL508 certified EN60950-1 certified CSA C22.2 No. 60950-01 certified EN55011 compliant EN50121-4 compliant CSA C22.2 No.107 certified EN61000-6-2 compliant EN61000-6-3 compliant 35VDC No Load Power Consumption Input Frequency Range E470721 2ms 400VAC 480VAC 17ms 20ms measured at 20MHz BW 10mVp-p continued on next page www.recom-power.com REV.: 2/2019 PDR-1 PDF
Документация на REDIN480-24/3AC 

Дата модификации: 07.06.2019

Размер: 568.1 Кб

8 стр.

    Публикации 1

    показать свернуть
    15 декабря 2020
    статья

    Европейский стандарт эффективности для AC/DC-преобразователей и продукция RECOM

    Александр Шрага (г. Москва) Показатели ряда AC/DC–преобразователей производства RECOM превосходят требования основных европейских стандартов по энергоэффективности. В марте 2010 года была одобрена европейская стратегия экономического... ...читать

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.