Product datasheet GV2ME21 Characteristics motor circuit breaker GV2-ME - 3 poles 3d - 17...23 A - thermomagnetic trip unit Range of product TeSys Device short name GV2ME Product or component type Circuit breaker Circuit breaker application Motor protection Poles description 3P Network type AC Control type Pushbutton Motor power kW 11 kW at 500 V AC 50/60 Hz 9 kW at 400...415 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz [In] rated current 23 A Magnetic tripping current 327 A Thermal protection adjustment range 17...23 A conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6 Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Connections - terminals Power circuit: screw clamp terminal 2 cable 1...6 mm² - cable stiffness: solid Power circuit: screw clamp terminal 2 cable 1.5...6 mm² - cable stiffness: flexible - without cable end Power circuit: screw clamp terminal 2 cable 1...4 mm² - cable stiffness: flexible - with cable end Complementary Network frequency 50/60 Hz Mounting mode Fixed Mounting support Plate Rail Mounting position Horizontal Vertical Trip unit technology Thermal-magnetic Phase failure sensitivity Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 [Ue] rated operational voltage 600 V AC 50/60 Hz conforming to CSA C22-2 No 14 600 V AC 50/60 Hz conforming to UL 508 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 600 V conforming to CSA C22-2 No 14 600 V conforming to UL 508 690 V conforming to IEC 60947-2 [Ith] conventional free air thermal current 23 A conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to CSA 50/60 Hz conforming to IEC 60947-4-1 50/60 Hz conforming to UL [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Power dissipation per pole 2.5 W Mechanical durability 100000 cycles Electrical durability 100000 cycles on AC-3 at 440 V In/2 Maximum number of switchings 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 1.7 N.m - on screw clamp terminal - cable 1...6 mm² 1.7 N.m - on screw clamp terminal - cable 1.5...6 mm² 1.7 N.m - on screw clamp terminal - cable 1...4 mm² Breaking capacity Icu 15 kA at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 1/2 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main PDF
Документация на GV2ME21 

Дата модификации: 31.05.2016

Размер: 233.2 Кб

2 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.