3UG4622-1AW30

ЦИФРОВОЕ РЕЛЕ КОНТРОЛЯ ТОКА, 22.5 MM FROM 0.1 ДО 10 A AC/DC OVERSHOOT AND UNDERSHOOT 24 ДО 240 V AC/DC DC AND AC 50 ДО 60 HZ START KICK AND SPIKE DELAY 0.1 ДО 20 S ГИСТЕРЕЗИС 0.01 ДО 0.5 A 1 ПЕРЕКИДНОЙ КОНТАКТWITH ИЛИ WITHOUT ERROR LOG SCREW TERMINAL
развернуть ▼ свернуть ▲

Файлы 2

показать свернуть
Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Current monitoring ■ Technical specifications 3UG46 21-.AA 3UG46 21-.AW 3UG46 22-.AA 3UG46 22-.AW 24 … 240 24 24 … 240 20.4 ... 264 20.4 ... 26.4 20.4 ... 264 General data Rated control supply voltage Us V 24 Rated frequency Hz 50/60 Operating range V 20.4 ... 26.4 Rated power W/VA 2/4 Width mm 22.5 Automatic/ manual RESET Availability time after application of Us ms 1000 Response time on reaching a switching threshold ms 450 Adjustable tripping delay time s 0.1 … 20 Adjustable ON-delay time s 0.1 … 20 Mains buffering time, min. ms 10 Rated insulation voltage Ui Degree of pollution 3; overvoltage category III according to VDE 0110 V 690 Rated impulse withstand voltage Uimp kV 6 Safe isolation according to EN 60947-1 V 300 Permissible ambient temperature • During operation • During storage °C °C -25 … +60 -40 … +85 EMC tests1) IEC 60947-1/ IEC 61000-6-2 / IEC 61000-6-4 Degree of protection • Enclosure • Terminals IP40 IP20 Vibration resistance according to IEC 60068-2-6 Hz/mm 1-6/15; 6-500.20 m/s2 Shock resistance according to IEC 60068 Part 2-27 g/ms 15/11 mm2 mm2 AWG Nm M3 (standard screwdriver size 2 and Pozidriv 2) 1 x (0.5 ... 4) / 2 x (0.5 ... 2.5) 1 x (0.5 ... 2.5) / 2 x (0.5 ... 1.5) 2 x (20 ... 14) 0.8 … 1.2 mm2 mm2 mm2 AWG 2 x (0.25 ... 1.5) 2 x (0.25 ... 1.5) 2 x (0.25 ... 1.5) 2 x (24 ... 16) Measuring range for single-phase AC/DC current A 0.003 … 0.6 Setting range for single-phase current A 0.003 ... 0.5 Load supply voltage V 24 Measuring accuracy % 5 Repeat accuracy at constant parameters % 1 Conductor cross-section • Screw terminals - Solid - Finely stranded with end sleeve - AWG conductors, solid or stranded - Tightening torque • Spring-loaded terminals - Solid - Finely stranded, with end sleeves according to DIN 46228 - Finely stranded - AWG conductors, solid or stranded 7 Measuring circuit 0.05 ... 10 Max. 3002) Max. 5003) 24 –1 digit Accuracy of digital display Deviations for temperature fluctuations 0.05 … 15 %/°C Hysteresis for single-phase current –0.1 0.1 ... 250 mA 0.01 ... 5 A Permissible overcurrent, continuous A 0.6 15 Permissible overcurrent, < 1 s A 5 50 Protection against destruction, DIAZED gL/gG A 2 16 Measuring circuit internal resistance, shunt mW 500 5 Load capacity of the output relay • Thermal current limit Ith A 5 Rated operational current Ie at • AC-15/24 ... 400 V • DC-13/24 V • DC-13/125 V • DC-13/250 V A A A A 3 1 0.2 0.1 Minimum contact load at 17 V DC mA 5 Output relay with DIAZED fuse gL/gG A 4 Electrical endurance AC15 Million 0.1 oper. cycles Endurance with contactor relay Million 10 oper. cycles Control circuit 1) Note: This is a Class A product. In the household environment this device may cause radio interference. In this case the user must introduce suitable measures. 7/72 Siemens LV 1 T · 2007 2) With safe isolation. 3) With easy isolation. Max. 3002) Max. 5003) PDF
Документация на 3UG4622-1AW30 

LV1_T_2007_EN SIRIUS; SENTRON; SIVACON

Дата модификации: 17.04.2007

Размер: 114.4 Кб

1 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.