TMR 2-1212WIN

TRACO
Baar, 11. December 2014 Cleaning Guideline Scope This guideline covers hermetically sealed board mounted Traco converters. We do not recommend washing insert moulded products, where it is difficult to get them dry inside. Please check also, if there is an additional comment about washing in the datasheet or application note of the concerned product. Note: We do generally not recommend washing...
развернуть ▼ свернуть ▲

Технические характеристики

показать свернуть
Монтаж
Выходная мощность
Количество каналов
Входное напряжение
Параметры выходов
Возможности
Комплекс защит короткого замыкания, перегрузка
Номинальное входное напряжение
Напряжение 1 выхода
Ток 1 выхода
Уровень пульсаций
КПД
Напряжение изоляции вход-выход
Размер 21.8×9.2×11.2 мм
Рабочая температура
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Аналоги 32

показать свернуть
Тип Наименование Корпус Упаковка i Монтаж P вых Каналов U вх Выход Возможности Защита U вх ном. U1 U2 U3 I1 I2 I3 Шум КПД Паралл. сх. Uиз. вх-вых Uиз. вх-общ Uиз. вых-общ Uиз. вых-вых Серт. медиц. T раб Примечания Карточка
товара
A- TEC 3-1212WI (TRACO)
 
A- TEC 3-1222WI (TRACO)
 
A- TMR 2-1222WIN (TRACO)
 
SIP87 в линейках 10 шт короткого замыкания, перегрузка
A- TMR 3-1212WI (TRACO)
 
SIP87 в линейках 10 шт TRACOPOWER - TMR 3-1212WI - DC/DC Converter Защита от КЗ: продолжительная с автовосстановлением
A- TMR 3-1222WI (TRACO)
 
SIP87 в линейках 10 шт DC-DC модульный преобразователь - Монтаж: на плату, SIP8; P вых: 3 Вт; #: 2; U вх: 4.5.... Защита от КЗ: продолжительная с автовосстановлением
A- TEC 2-1212WI (TRACO)
 
A- TEC 2-1222WI (TRACO)
 
A- DLC03A-12 (MW)
 
DIP168 в линейках 36 шт короткого замыкания, перегрузки, перенапряжения
A- MDD03F-12 (MW)
 
11 шт
A- MDD03G-12 (MW)
 
11 шт
A- SLC03A-12 (MW)
 
DIP168 в линейках 36 шт короткого замыкания, перегрузки, перенапряжения
A- SMU02M-12 (MW)
 
SIP4 в линейках 42 шт
A- B0512S-2WR2 (MORNSUN)
 
SIP76 в линейках 100 шт
A- B0512S-2WR3 (MORNSUN)
 
в линейках 300 шт
A- B1212S-2WR2 (MORNSUN)
 
SIP76 1 шт
A- B1212S-2WR3 (MORNSUN)
 
в линейках 50 шт
A- B1212XT-2WR3 (MORNSUN)
 
в линейках 50 шт
A- WRA0512S-3WR2 (MORNSUN)
 
SIP87 20 шт
A- WRA1212P-3WR2 (MORNSUN)
 
в линейках 30 шт
 
A- WRA1212S-3WR2 (MORNSUN)
 
SIP87 в линейках 2 шт
A- WRA1212ST-3WR2 (MORNSUN)
 
в линейках 20 шт
A- WRA1212ZP-3WR2 (MORNSUN)
 
в линейках 30 шт EN55024, light industry level, criteria A
A- WRA2412P-3WR2 (MORNSUN)
 
в линейках 100 шт
 
A- WRA2412S-3WR2 (MORNSUN)
 
SIP7 в линейках 6 шт
A- WRA2412ZP-3WR2 (MORNSUN)
 
в линейках 5 шт EN55024, light industry level, criteria A
A- WRB1212P-3WR2 (MORNSUN)
 
в линейках 30 шт
 
A- WRB1212S-3WR2 (MORNSUN)
 
SIP87 в линейках 100 шт
A- WRB1212ZP-3WR2 (MORNSUN)
 
в линейках 10 шт EN55024, light industry level, criteria A
A- WRB2412P-3WR2 (MORNSUN)
 
в линейках 20 шт
 
A- WRB2412S-3WR2 (MORNSUN)
 
SIP87 в линейках 100 шт
A- F1212S-2WR3 (MORNSUN)
 
в линейках 50 шт
A- F1212XT-2WR3 (MORNSUN)
 
в линейках 30 шт

Файлы 2

показать свернуть
Baar, 11. December 2014 Cleaning Guideline Scope This guideline covers hermetically sealed board mounted Traco converters. We do not recommend washing insert moulded products, where it is difficult to get them dry inside. Please check also, if there is an additional comment about washing in the datasheet or application note of the concerned product. Note: We do generally not recommend washing or cleaning electronic components. You should avoid it, if it is not absolutely necessary. It may reduce the reliability of the involved components in your application. Board cooling prior to cleaning process Converters and their associated application PCB assemblies should not be wash-cleaned after soldering until they had the opportunity to cool within the cleaning solution temperature. This will prevent vacuum absorption of the cleaning liquid into the module between the pins and the potting during cooling. Cleaning agents Cleaning method Classification Cleaning agents Water type Deionized water Ultrasonic wave Solvent type IPA Note: In general, the liquid temperature shall be less than 60°C. Cleaning process In aqueous cleaning, it is preferred to have an in-line cleaner system consisting of several cleaning stages (prewash, wash, rinse, final rinse, and drying). Deionised (DI) water is recommended for aqueous cleaning; the minimum resistively level is 1MΩ-cm. Tap-water quality varies per region in terms of hardness, chloride, and solid contents. Therefore, the use of tap water is not recommended for aqueous cleaning. Note: The total time of ultrasonic wave shall be less than 3 minutes. Drying After cleaning, assure that everything will be dry enough, that the moisture and other potential contaminants will not be present anymore. Use an air circulating chamber (e.g. 0.5-0.7m3/s) and thermal oven at 80-100°C (during 20-120min, depending on assembling, structure, components). Handheld air guns are not recommended. It is on customer’s own responsibility to ensure all components are dry. Product post-wash external appearance The marking or date-code may fade or disappear after cleaning. That does not concern the performance of the converter. Andreas Flühler, Head of Technical Services PDF
Рекомендации по промывке и сушке 

Cleaning Guideline

Дата модификации: 02.02.2021

Размер: 79 Кб

1 стр.

DC/DC Converters TMR 2WIN Series, 2 Watt CB Features ◆ Ultra-wide 4:1 input range ◆ Compact SIP-8 package ◆ Temperature range –40 to +90°C Scheme (up to +75°C at full load) ◆ ◆ ◆ ◆ ◆ ◆ ◆ High efficiency of 82% Excellent load and line regulation Continuouse short-circuit protection Overload protection I/O isolation 1500 VDC Remote On/Off control The TMR-2WIN series is a family of isolated 2 W DC/DC converter modules with accurately regulated output voltages and ultra-wide 4:1 input voltage ranges. They require no minimum load and are protected against overload and short circuit. An excellent efficiency along with the use of high grade components allows a compact construction in SIP-8 package; even the converters can reliably operate in an ambient temperature of –40°C to +75°C at full load and up to 90°C with 50% power derating. Typical applications for these converters are distributed power architectures in communication, instrumentation and industrial electronics, everywhere where space on the PCB is critical. 3-year product warranty Models Ordercode Input voltage range TMR 2-1210WIN Output voltage Output current max. Efficiency typ. 3.3 VDC 500 mA 75 % TMR 2-1211WIN 5 VDC 400 mA 80 % TMR 2-1212WIN 12 VDC 167 mA 82 % TMR 2-1213WIN 4.5 – 18 VDC 15 VDC 134 mA 82 % ±5 VDC ±200 mA 80 % TMR 2-1222WIN ±12 VDC ±83 mA 82 % TMR 2-1223WIN ±15 VDC ±67 mA 82 % TMR 2-2410WIN 3.3 VDC 500 mA 75 % TMR 2-1221WIN (12 VDC nominal) TMR 2-2411WIN 5 VDC 400 mA 80 % TMR 2-2412WIN 12 VDC 167 mA 82 % TMR 2-2413WIN TMR 2-2421WIN 9 – 36 VDC (24 VDC nominal) 15 VDC 134 mA 82 % ±5 VDC ±200 mA 80 % TMR 2-2422WIN ±12 VDC ±83 mA 82 % TMR 2-2423WIN ±15 VDC ±67 mA 82 % TMR 2-4810WIN 3.3 VDC 500 mA 74 % TMR 2-4811WIN 5 VDC 400 mA 80 % 12 VDC 167 mA 82 % TMR 2-4812WIN TMR 2-4813WIN TMR 2-4821WIN 18 – 75 VDC (48 VDC nominal) 15 VDC 134 mA 82 % ±5 VDC ±200 mA 80 % TMR 2-4822WIN ±12 VDC ±83 mA 82 % TMR 2-4823WIN ±15 VDC ±67 mA 82 % http://www.tracopower.com Page 1 of 3 PDF
Документация на серию TMR2WIN 

Datasheet

Дата модификации: 14.04.2015

Размер: 145.7 Кб

3 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.