TMR 9-4811

Baar, 11. December 2014 Cleaning Guideline Scope This guideline covers hermetically sealed board mounted Traco converters. We do not recommend washing insert moulded products, where it is difficult to get them dry inside. Please check also, if there is an additional comment about washing in the datasheet or application note of the concerned product. Note: We do generally not recommend washing...
развернуть ▼ свернуть ▲

Технические характеристики

показать свернуть
Монтаж
Выходная мощность
Количество каналов
Входное напряжение
Параметры выходов
Возможности
Комплекс защит
Номинальное входное напряжение
Напряжение 1 выхода
Ток 1 выхода
Уровень пульсаций
КПД
Напряжение изоляции вход-выход
Размер 21.8×9.6×11.2 мм
Рабочая температура
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Аналоги 24

показать свернуть
Тип Наименование Корпус Упаковка i Монтаж P вых Каналов U вх Выход Возможности Защита U вх ном. U1 U2 U3 I1 I2 I3 Шум КПД Паралл. сх. Uиз. вх-вых Uиз. вх-общ Uиз. вых-общ Uиз. вых-вых Серт. медиц. T раб Примечания Карточка
товара
A- TMR 9-4811WI (TRACO) SIP87 в линейках 10 шт
A- THN 10-2421WIR (TRACO) КЗ, перегрузка, перенапряжение
A- TEN 8-4811 (TRACO) DIP2410 в линейках 10 шт DC-DC модульный преобразователь - Монтаж: на плату, DIP24; P вых: 8 Вт; #: 1; U вх: 36.... короткого замыкания, перегрузки Защита от КЗ: продолжительная с автовосстановлением
A- THL 10-1211 (TRACO) 1 шт
A- TMR 9-2411WI (TRACO) SIP87 в линейках 10 шт
A- K7805-2000R3 (MORNSUN) SIP3 в линейках 500 шт
A- SKE10B-05 (MW) 2X1INCH в линейках 10 шт DC-DC модульный преобразователь - Монтаж: на плату, 2x1 inch; P вых: 10 Вт; #: 1; U вх:... короткого замыкания, перегрузки
A- NSD10-12S5 (MW) 2X1INCH на поддоне 300 шт Преобразователь напряжения DC-DC на плату. 10Вт,Uвх=9.8-36В, Uвых=5В/2А,изоляция 1КВ AC... перегрузки, перенапряжения, перегрева EN55024, light industry level, criteria A
A- NSD10-48S5 (MW) 2X1INCH на поддоне 10 шт Преобразователь напряжения DC-DC на плату. 10Вт,Uвх=22-72В, Uвых=5В/2А,изоляция 1КВ AC ... перегрузки, перенапряжения, перегрева EN55024, light industry level, criteria A
A- RP10-2405SEW/P/M2 (RECOM) 2X1INCH в линейках 9 шт DC-DC модульный преобразователь - Монтаж: на плату, 2x1 inch; P вых: 10 Вт; #: 1; U вх:...
A- AM10E-2405SZ (AIMTEC) 2X1INCH в линейках 10 шт DC-DC модульный преобразователь - Монтаж: на плату, 2x1 inch; P вых: 10 Вт; #: 1; U вх:...
A- THN 10-4811WIR (TRACO) 12 шт КЗ, перегрузка, перенапряжение
A- THN 10-7211WIR (TRACO) 9 шт КЗ, перегрузка, перенапряжение
A- TEN 8-2411 (TRACO) DIP2410 в линейках 10 шт короткого замыкания, перенапряжения, перегрева Защита от КЗ: продолжительная с автовосстановлением
A- THN 10-4821WIR (TRACO) КЗ, перегрузка, перенапряжение
A- THN 10-7221WIR (TRACO) КЗ, перегрузка, перенапряжение
A- THD 12-2421WI (TRACO) DIP2410 в линейках 10 шт DC-DC модульный преобразователь - Монтаж: на плату, DIP24; P вых: 12 Вт; #: 2; U вх: 9....
A- THD 12-4821WI (TRACO) DIP2410
A- THL 10-2421 (TRACO)
A- THR 10-2411WI (TRACO) КЗ, перегрузка, перенапряжение
A- THR 10-4811WI (TRACO) КЗ, перегрузка, перенапряжение
A- THR 10-7211WI (TRACO) КЗ, перегрузка, перенапряжение
A- TEL 8-2411WI (TRACO) в линейках 10 шт короткого замыкания, перенапряжения, перегрева Защита от КЗ: продолжительная с автовосстановлением
A- TSR 1.5-2450E (TRACO) SIP3 4 шт

Файлы 2

показать свернуть
Baar, 11. December 2014 Cleaning Guideline Scope This guideline covers hermetically sealed board mounted Traco converters. We do not recommend washing insert moulded products, where it is difficult to get them dry inside. Please check also, if there is an additional comment about washing in the datasheet or application note of the concerned product. Note: We do generally not recommend washing or cleaning electronic components. You should avoid it, if it is not absolutely necessary. It may reduce the reliability of the involved components in your application. Board cooling prior to cleaning process Converters and their associated application PCB assemblies should not be wash-cleaned after soldering until they had the opportunity to cool within the cleaning solution temperature. This will prevent vacuum absorption of the cleaning liquid into the module between the pins and the potting during cooling. Cleaning agents Cleaning method Classification Cleaning agents Water type Deionized water Ultrasonic wave Solvent type IPA Note: In general, the liquid temperature shall be less than 60°C. Cleaning process In aqueous cleaning, it is preferred to have an in-line cleaner system consisting of several cleaning stages (prewash, wash, rinse, final rinse, and drying). Deionised (DI) water is recommended for aqueous cleaning; the minimum resistively level is 1MΩ-cm. Tap-water quality varies per region in terms of hardness, chloride, and solid contents. Therefore, the use of tap water is not recommended for aqueous cleaning. Note: The total time of ultrasonic wave shall be less than 3 minutes. Drying After cleaning, assure that everything will be dry enough, that the moisture and other potential contaminants will not be present anymore. Use an air circulating chamber (e.g. 0.5-0.7m3/s) and thermal oven at 80-100°C (during 20-120min, depending on assembling, structure, components). Handheld air guns are not recommended. It is on customer’s own responsibility to ensure all components are dry. Product post-wash external appearance The marking or date-code may fade or disappear after cleaning. That does not concern the performance of the converter. Andreas Flühler, Head of Technical Services PDF
Рекомендации по промывке и сушке 

Cleaning Guideline

Дата модификации: 02.02.2021

Размер: 79 Кб

1 стр.

DC/DC Converters TMR 9 Series, 9 Watt Features ◆ Highest power density in SIP package ◆ Wide 2:1 input voltage range ◆ Ultra-compact SIP-8 package ◆ Smallest footprint 9W converter ◆ Full SMD design ◆ Temperature range –40° to +85°C ◆ High efficiency up to 90% ◆ Indefinite short-circuit protection ◆ I/O isolation 1600 VDC ◆ Remote On/Off control ◆ Fully RoHS compliant ◆ 3-year product warranty UL 60950-1 The TMR-9 series is a new family of isolated 9W dc-dc converter modules with regulated output, featuring wide 2:1 input voltage ranges. The product comes in a ultra-compact SIP-8 metal package with a small footprint occupying only 2.0 cm2 (0.3 square in.) of board space. An excellent efficiency allows –40° to +60°C operation temperatures without derating. Further features include remote On/Off control and continuous short circuit protection. The very compact dimensions of these converters make them an ideal solution for many space critical applications in communication equipment, instrumentation and industrial electronics. Models Order code TMR 9-1210 TMR 9-1211 TMR 9-1219 TMR 9-1212 TMR 9-1213 TMR 9-1215 TMR 9-1221 TMR 9-1222 TMR 9-1223 TMR 9-2410 TMR 9-2411 TMR 9-2419 TMR 9-2412 TMR 9-2413 TMR 9-2415 TMR 9-2421 TMR 9-2422 TMR 9-2423 TMR 9-4810 TMR 9-4811 TMR 9-4819 TMR 9-4812 TMR 9-4813 TMR 9-4815 TMR 9-4821 TMR 9-4822 TMR 9-4823 http://www.tracopower.com Input voltage range 9 – 18 VDC (12 VDC nominal) 18 – 36 VDC (24 VDC nominal) 36 – 75 VDC (48 VDC nominal) Output voltage 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±12 VDC ±15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±12 VDC ±15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC ±5 VDC ±12 VDC ±15 VDC Output current max. 2000 mA 1600 mA 1000 mA 750 mA 600 mA 375 mA ±800 mA ±375 mA ±300 mA 2000 mA 1600 mA 1000 mA 750 mA 600 mA 375 mA ±800 mA ±375 mA ±300 mA 2000 mA 1600 mA 1000 mA 750 mA 600 mA 375 mA ±800 mA ±375 mA ±300 mA Efficiency typ. 81 % 85 % 87 % 88 % 89 % 89 % 85 % 88 % 89 % 82 % 85 % 88 % 89 % 90 % 90 % 86 % 89 % 87 % 82 % 85 % 88 % 89 % 89 % 89 % 86 % 87 % 87 % Page 1 of 3 PDF
Документация на TMR 9-4811 

Дата модификации: 07.10.2016

Размер: 182.7 Кб

4 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.