Серия DC-DC модульных преобразователей A03_B03_S-1WR3

Mornsun

Общие характеристики

Раздел DC-DC модульные преобразователи
Монтаж
Выходная мощность
Количество каналов
Входное напряжение
Возможности
Комплекс защит
Номинальное входное напряжение
Напряжение изоляции вход-выход
Размер 19.65×6×10.16 мм
Рабочая температура

Документация на серию A03_B03_S-1WR3

DC/DC Converter A03_S-1WR3& B03_LS-1WR3 series 1W isolated DC-DC converter Fixed input voltage and unregulated dual/single output FEATURES  Continuous short-circuit protection  No-load input current as low as 10mA  Operating ambient temperature range: -40℃ to +105℃  High efficiency up to 85%  I/O isolation test voltage: 1.5k VDC  Industry standard pin-out  SIP package Patent Protection RoHS A03_S-1WR3 & B03_LS-1WR3 series are specially designed for applications where an isolated (two isolated) voltage is required in a distributed power supply system. They are suitable for: pure digital circuits, low frequency analog circuits, relay-driven circuits and data switching circuits. Selection Guide Input Voltage(VDC) -- Output Full Load Efficiency(%) Capacitive Load(µF)* Max./Min. Min./Typ. Max. ±3.3 ±152/±15 74/78 1200 A0305S-1WR3 ±5 ±100/±10 78/82 1200 A0309S-1WR3 ±9 ±56/±6 81/85 470 A0312S-1WR3 ±12 ±42/±5 78/82 220 A0315S-1WR3 ±15 ±34/±4 78/82 220 ±24 ±21/±2 80/84 100 3.3 303/30 75/79 2400 B0305LS-1WR3 5 200/20 78/82 2400 B0309LS-1WR3 9 111/11 81/85 1000 B0312LS-1WR3 12 83/8 78/82 560 B0315LS-1WR3 15 67/7 78/82 560 B0324LS-1WR3 24 42/4 80/84 220 Certification Part No. Nominal Voltage Current(mA) ( Range ) (VDC) A0303S-1WR3 A0324S-1WR3 B0303LS-1WR3 3.3 (2.97-3.63) Note: *The specified maximum capacitive load for positive and negative output is identical. Input Specifications Item Operating Conditions Input Current (full load / no-load) 3.3VDC input Min. Typ. Max. 3.3VDC output -- 384/10 405/-- Others output -- 370/18 389/-- -- 15 -- -0.7 -- 5 Reflected Ripple Current* Surge Voltage (1sec. max.) 3.3 VDC input Input Filter Unit mA VDC Capacitance filter Hot Plug Unavailable Note: * Refer to DC-DC Converter Application Notes for detailed description of reflected ripple current test method. Output Specifications Item Operating Conditions Min. Voltage Accuracy Linear Regulation Typ. Max. Unit See output regulation curve(Fig. 1) Input voltage change: ±1% 3.3 VDC output -- -- ±1.5 Other output -- -- ±1.2 2021.11.15-A/0 -- Page 1 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на серию A03_B03_S-1WR3 

A03_S-1WR3 & B03_LS-1WR3 Keywords:

Дата модификации: 21.11.2022

Размер: 1.31 Мб

5 стр.

    Товары серии A03_B03_S-1WR3

    Наименование i Упаковка Выход U1 I1 КПД
    B0303LS-1WR3 (MORNSUN)
     
    в линейках 42 шт
    B0305LS-1WR3 (MORNSUN)
     
    в линейках 20 шт
    B0309LS-1WR3 (MORNSUN)
     
    в линейках 10 шт
    B0312LS-1WR3 (MORNSUN)
     
    B0315LS-1WR3 (MORNSUN)
     
    B0324LS-1WR3 (MORNSUN)