Серия DC-DC модульных преобразователей H_CS_2WR3

Общие характеристики

Раздел DC-DC модульные преобразователи
Монтаж
Выходная мощность
Количество каналов
Входное напряжение
Возможности
Комплекс защит
Номинальное входное напряжение
Напряжение изоляции вход-выход
Размер 27.4×9.5×12 мм
Рабочая температура

Документация на серию H_CS_2WR3

DC/DC Converter H12_CS-2WR3 FEATURES 2 W isolated DC-DC converter Fixed input voltage, regulated output  Continuous short-circuit protection  Operating ambient temperature range:-40℃ to +105℃  Meets 8kV impact withstand voltage  I/O isolation test voltage 5k VAC or 7k VDC, reinforced insulation  Industry standard pin-out  Electrical clearance and creepage distance above 16mm  Meets CTI level 1  Isolation capacitance as low as 7pF Patent Protection RoHS  High efficiency up to 84% H12_CS-2WR3 is specifically designed for applications where high voltage power systems such as photovoltaic and energy storage need to generate a set of voltage isolated from the input power supply. The design refers to IEC 62109-1 and IEC 62477-1 to meet the isolation requirements of 1500V system. It is suitable for: 1. Where the voltage of the input power supply is stable (voltage variation: ±10%Vin); 2. Where isolation is necessary between input and output (isolation voltage ≤5k VAC or 7k VDC); 3. Where has high requirement of Output voltage stability; Selection Guide Input Voltage (VDC) Certification Part No. Nominal (Range) H1205CS-2WR3 12 (10.8-13.2) -H1212CS-2WR3 Output Full Load Capacitive Load(µF) (VDC) Max./Min. Efficiency (%) Min./Typ. 5 400/40 80/83 1000 12 167/17 81/84 470 Voltage Current(mA) Max. Input Specifications Item Operating Conditions Input Current (full load / no-load) 12VDC input Min. Typ. Max. 5VDC output -- 217/15 -- 12VDC output -- 209/15 -- -- 30 -- -0.7 -- 18 Reflected Ripple Current* Surge Voltage (1sec. max.) Input Filter Unit mA VDC Capacitance Filter Hot Plug Unavailable Note: * Refer to DC-DC Converter Application Notes for detailed description of reflected ripple current test method. Output Specifications Item Operating Conditions Min. Voltage Accuracy Linear Regulation Input voltage change: ±1% Load Regulation 10%-100% load Ripple & Noise* 20MHz bandwidth Temperature Coefficient Full load Short-circuit Protection Typ. Max. Unit See output regulation curves(Fig. 1) 5VDC output -- -- 12VDC output -- -- 5VDC output -- 7 20 12VDC output -- 7 15 -- 50 150 mVp-p -- ±0.02 -- %/℃ ±1.2 -% Continuous, self-recovery Note:* The “parallel cable” method is used for Ripple and Noise test, please refer to DC-DC Converter Application Notes for specific information. 2022.02.07-A/0 Page 1 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на серию H_CS_2WR3 

H12_CS-2WR3 Keywords:

Дата модификации: 07.02.2022

Размер: 1.5 Мб

4 стр.

    Товары серии H_CS_2WR3

    Наименование i Упаковка Выход U1 U2
    H1205CS-2WR3 (MORNSUN)
     
     
    H1212CS-2WR3 (MORNSUN)