Серия трансформаторов TTLHE10-20B

Общие характеристики

Раздел Трансформаторы
Применение Flyback трансформатор для SCM1710A
Габарит
Тип монтажа
Рабочая температура

Документация на серию TTLHE10-20B

AC/DC Transformer TTLHE10-20BxxD Series 3000VAC isolation test voltage, EFD15, FEATURES flyback transformer  85 ~ 264VAC wide input voltage range  EFD15 Bobbin  Meets UL/EN 62368 standards RoHS TTLHE10-20BxxD transformer series feature with 3000VAC primary to secondary isolation, an operating ambient temperature range of -40℃ ~ +110℃. It can be used with our control IC SCM1710ASA to achieve flyback power supply design with wide input volatge range and various protection functions and superior EMI performance. Selection Guide Part No. Input Voltage (VAC) Output Voltage (VDC) Output Current (mA) Auxiliary Voltage (VDC) Auxiliary Current (mA) Typical Power (W) Typical Operating Frequency (kHz) TTLHE10-20B05D 85 ~ 264 5 2000 20.00 20 10 65 TTLHE10-20B12D 85 ~ 264 12 900 18.36 20 10 65 Note: Refer to Schematic for pins and phase points of the transformers. Electrical Specifications Inductance (uH) Input Leakage Inductance Inductance Max. DCR(mΩ) Typ. ① Part No. N1 N2 N3 K (Flux Density Factor) (Gauss/A) TTLHE10-20B05D 960.00±10% 60.00 2400 29 835 5299 TTLHE10-20B12D 960.00±10% 60.00 2400 113 682 5299 Notes: ①The test signal of the inductance are 10kHz and 100mV, test the leakage inductance of N1 based on N2 and N3 are shorted; ②To ensure the transformer will not saturate in all of the applications and conditions, the peak flux density(Bm) should remain below 3000Gauss. Use the following formula to calculate the peak flux density: Bm=K*Ipk, Ipk stands for the peak current of input, which unit is A; ③Approximate transformer core loss(Pcv) can be calculated as following formula: Pcv=3.9E-14*f1.82* △ B2.59, the unit of Pcv is W, f stands for operating frequency, which unit is kHz, △B is the operating flux density, which unit is Gauss. △B can be calculated as: △B=K*△I. General Specifications Item Operating Conditions Min. N1, N3 to N2 Electric Strength Test for1 minute, leakage current <5mA 3000 -- -- VAC N1 to N3 Electric Strength Test for1 minute, leakage current <1mA 1000 -- -- VDC Operating Temperature -40 -- +110 Storage Temperature -40 -- +110 -- -- 95 Isolation ① ② Storage Humidity Soldering Temperature Notes: Non-condensing Typ. Max. Unit ℃ %RH Wave-soldering 260 ± 5℃; time: 5 - 10s Manual-welding 360 ± 10℃; time: 3 - 5s ①The temperature of the transformer (ambient plus temperature rise) should be within the operating temperature range; ②The storage temperature of the transformer only. ③To meet the safety requirements, you need to use glue. Mechanical Specifications Weight TTLHE10-20B05D TTLHE10-20B12D 5.20g (Typ.) 2019.07.08-A/2 Page 1 of 3 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на серию TTLHE10-20B 

Subject:

Дата модификации: 15.08.2019

Размер: 427.3 Кб

3 стр.

    Товары серии TTLHE10-20B

    Наименование i Упаковка Коэффициент
    TTLHE10-20B05D (MORNSUN)
     
    на поддоне 300 шт
    TTLHE10-20B12D (MORNSUN)
     
    на поддоне 300 шт