Серия DC-DC модульных преобразователей URA1D_YMD-6WR3

Общие характеристики

Раздел DC-DC модульные преобразователи
Монтаж
Выходная мощность
Входное напряжение
Комплекс защит
Номинальное входное напряжение
КПД
Напряжение изоляции вход-выход
Размер 25.4×25.4×11.7 мм
Рабочая температура

Документация на серию URA1D_YMD-6WR3

DC/DC Converter URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series 6W isolated DC-DC converter Ultra-wide input voltage and regulated dual/single output FEATURES  Ultra-wide 4:1 input voltage range  High efficiency up to 86%  I/O isolation test voltage: 2.25k VDC  Operating ambient temperfuature range: -40℃ to +85℃  Input under-voltage protection, output shortcircuit, over-current, over-voltage protection  Low ripfiple & noise  Input reverse polarity protection available with chassis(A2S ) or Din-Rail mounting (A4S) version  Meets EN50155 railway standard Patent Protection  Industry standard pin-out RoHS EN62368-1 BS EN62368-1 URA1D_YMD-6WR3 & URB1D_YMD-6WR3 series are isolated 6W DC-DC converter products with 40-160VDC input voltage with efficiencies of up to 86%, input to output isolation is tested with 2250VDC and the converter safely operate ambient temperature of -40℃ to +85℃, input under-voltage protection, output short-circuit, over-current, over-voltage protection. They are widely used in railway vehicle applications using 72V, 96V and 110V battery voltages. Selection Guide EN/BS EN Input Voltage (VDC) Nominal② Max.③ (Range) Output Voltage (VDC) Current (mA) Max./Min. Full Load ④ Efficiency (%) Min./Typ. Capacitive Load⑤ (µF)Max. URA1D05YMD-6WR3 ±5 ±600/0 78/80 470 URA1D12YMD-6WR3 ±12 ±250/0 82/84 100 URA1D15YMD-6WR3 ±15 ±200/0 83/85 100 Part No. Certification ① 110 (40-160) 170 5 1200/0 78/80 1000 12 500/0 82/84 470 URB1D15YMD-6WR3 15 400/0 83/85 220 URB1D24YMD-6WR3 24 250/0 84/86 100 URB1D05YMD-6WR3 URB1D12YMD-6WR3 Note: ①Use “H” suffix for heat sink mounting, “A2S” suffix for chassis mounting and “A4S” suffix for Din-Rail mounting. We recommend to choose modules with a heat sink for enhanced heat dissipation and applications with extreme temperature requirements; ②The minimum input voltage and starting voltage of A2S and A4S Model are 1VDC higher than those of DIP package due to input reverse polarity protection function; ③Exceeding the maximum input voltage may cause permanent damage; ④Efficiency is measure at nominal input voltage and rated output load; efficiencies for A2S and A4S Model’s is decreased by 2% due to the input reverse polarity protection circuit. ⑤The specified maximum capacitive load for Vo1 and Vo2 output is identical. Input Specifications Item Min. Typ. Max. Input Current (full load / no-load) Nominal input voltage Operating Conditions -- 68/3 70/8 Reflected Ripple Current -- 25 -- -0.7 -- 180 Nominal input voltage Surge Voltage (1sec. max.) Start-up Voltage -- -- 40 Input Under-voltage Protection 28 33 -- -- 10 -- Start-up Time Input Filter Hot Plug Nominal input voltage & constant resistance load Unit mA VDC ms Pi filter Unavailable 2021.12.30-A/9 Page 1 of 8 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на URB1D24YMD-6WR3 

URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Keywords:

Дата модификации: 05.01.2022

Размер: 2.87 Мб

8 стр.

DC/DC Converter URA1D_YMD-6WR3 & URB1D_YMD-6WR3 Series FEATURES 6W, ultra wide input isolated & regulated dual / single output DC-DC converter            RoHS Ultra wide input voltage range (4:1) High efficiency up to 86% Isolation voltage: 2.25K VDC Operating temperature range: -40℃ to +85℃ Input Under-voltage Protection, Output short circuit, over-current, over–voltage protection Low ripple & noise Reverse voltage protection available with A2S(Chassis mounting) or A4S(35mm DIN-Rail mounting) EN62368 approval(URA1D_YMD-6WR3) EN60950 approval(URB1D_YMD-6WR3) Meets requirements of railway standard EN50155(URB1D_YMD-6WR3) International standard pin-out Patent Protection URA1D_YMD-6WR3 & URB1D_YMD-6WR3 series are isolated 6W DC-DC products with 40-160VDC input voltage .They feature efficiency up to 86%, 2250VDC isolation, operating temperature of -40 ℃ to +85℃, Input Under-voltage Protection, Output short circuit, over-current, over–voltage protection. Railway vehicle electronic equipment widely used in 72V, 96V and 110V. Selection Guide Part No. certification CE ① Output Output Voltage Output Current (mA) (Max./Min.) (VDC) Efficiency (%,Min./Typ.) @ Full Load Max. Capacitive Load(µF) ③ URA1D05YMD-6WR3 ±5 ±600/0 78/80 470 URA1D12YMD-6WR3 ±12 ±250/0 82/84 100 URA1D15YMD-6WR3 ±15 ±200/0 83/85 100 110 (40-160) 5 1200/0 78/80 1000 12 500/0 82/84 470 URB1D15YMD-6WR3 15 400/0 83/85 220 URB1D24YMD-6WR3 24 250/0 84/86 100 URB1D05YMD-6WR3 CE Input Voltage (VDC) Nominal ② Max. (Range) URB1D12YMD-6WR3 170 Note: ①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting , with suffix “A4S” are DIN-Rail mounting, for example URB1D05YMD-6WHR3A2S is chassis mounting of with heat sink, URB1D05YMD-6WR3A4S is DIN-Rail mounting of without heat sink; If the application has a higher requirement for heat dissipation, you can choose modules with heat sink; ②Absolute maximum rating without damage on the converter, but it isn't recommended; ③Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection, minimum efficiency greater than Min.-2 is qualified. Input Specifications Item Operating Conditions Min. Typ. Max. Input Current (full load / no-load) Nominal input voltage -- 68/3 70/8 Reflected Ripple Current Nominal input voltage -- 25 -- -0.7 -- 180 -- -- 40 28 33 -- -- 10 -- Surge Voltage (1sec. max.) Starting Voltage Shutdown Voltage Starting Time Nominal input voltage & constant resistance load Input Filter mA VDC ms Pi filter Hot Plug Module switch on Ctrl* Unit Module switch off Input current when switched off Unavailable Ctrl suspended or connected to TTL high level (3.5-12VDC) Ctrl pin connected to GND or low level (0-1.2VDC) mA -3 8 Note: *The voltage of Ctrl pin is relative to input pin GND. 2018.06.05-A/4 Page 1 of 8 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на серию URA1D_YMD-6WR3 

Subject:

Дата модификации: 05.06.2018

Размер: 2.71 Мб

8 стр.

    Товары серии URA1D_YMD-6WR3

    Наименование i Упаковка Каналов Выход Возможности U1 U2 I1 I2
    URA1D05YMD-6WR3 (MORNSUN)
     
    URA1D12YMD-6WR3 (MORNSUN)
     
    URA1D15YMD-6WR3 (MORNSUN)
     
    URB1D05YMD-6WHR3 (MORNSUN)
     
    в линейках 40 шт стандарт, теплоотвод, изолированный
    URB1D05YMD-6WR3 (MORNSUN)
     
    в линейках 50 шт
    URB1D12YMD-6WR3 (MORNSUN)
     
    в линейках 41 шт
    URB1D15YMD-6WR3 (MORNSUN)
     
    1 шт
    URB1D24YMD-6WR3 (MORNSUN)
     
    1 шт