Серия DC-DC модульных преобразователей UWE/F_S-1WR3

Общие характеристики

Раздел DC-DC модульные преобразователи
Монтаж
Выходная мощность
Входное напряжение
Возможности
Комплекс защит
Номинальное входное напряжение
КПД
Напряжение изоляции вход-выход
Размер 22×9.5×12 мм
Рабочая температура

Документация на серию UWE/F_S-1WR3

DC/DC Converter UWE/F_S-1WR3 series FEATURES 1W isolated DC-DC converter in SIP package Ultra-wide input and regulated single/dual output  Ultra-wide input voltage range (8:1)  High efficiency up to 74%  No-load power consumption as low as 0.12W  I/O isolation test voltage 3K VDC  Operating ambient temperature range: -40℃ to +105℃  Input under-voltage, output short-circuit , over-current protection  Industry standard pin-out Patent Protection RoHS  EN62368 approved UWE/F_S-1WR3 series of isolated 1W DC-DC products with an ultra-wide 8:1 input voltage range. They feature efficiencies of up to 74%, 3000VDC input to output isolation, operating ambient temperature range of -40 ℃ to +105 ℃ , input under-voltage protection, output over-current, short circuit protection and they are widely used in applications such as medical care, industrial control, electric power, instruments and communication fields. Selection Guide Input Voltage (VDC) Certification Current (mA) Max./Min. Full Load Efficiency② Min./Typ. Max. Capacitive UWE1205S-1WR3 ±5 ±100 69/71 220 UWE1212S-1WR3 ±12 ±42 72/74 150 ±15 ±33 72/74 68 5 200 69/71 470 9 111 69/72 220 UWF1212S-1WR3 12 83 72/74 330 UWF1215S-1WR3 15 67 72/74 220 UWE1215S-1WR3 CE Output Voltage (VDC) Part No. UWF1205S-1WR3 UWF1209S-1WR3 Nominal (Range) 12 (4.5-36) Max. ① 40  Load (µF) Note: ① Exceeding the maximum input voltage may cause permanent damage; ② Efficiency is measured at nominal input voltage and rated output load; ③ The specified maximum capacitive load value for positive and negative output is identical. Input Specifications Item Input Current (full load / no-load) Operating Conditions Min. Typ. Max. 5V/±5V output -- 117/10 123/15 Others -- 114/10 120/15 Reflected Ripple Current Surge Voltage (1sec. max.) Start-up Voltage Input Under-voltage Protection -- 50 -- -0.7 -- 50 -- -- 4.5 3.5 -- 2.5 Input Filter Unit mA VDC Capacitance Filter Hot Plug Unavailable Output Specifications Item Output Voltage Accuracy Line Regulation Operating Conditions Min. Typ. Max. -- ±1 ±3 Vo1 -- -- ±0.5 Vo2 -- -- ±1 0% -100% load Full load, the input voltage is from low to high 2020.08.11-A/1 Unit % Page 1 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на серию UWE/F_S-1WR3 

UWE/F_S-1WR3 series Keywords:

Дата модификации: 18.08.2020

Размер: 1.03 Мб

4 стр.

    Товары серии UWE/F_S-1WR3

    Наименование i Упаковка Каналов Выход U1 U2 I1 I2
    UWE1205S-1WR3 (MORNSUN)
     
    1 шт
    UWE1212S-1WR3 (MORNSUN)
     
    UWE1215S-1WR3 (MORNSUN)
     
    UWF1205S-1WR3 (MORNSUN)
     
    22 шт
    UWF1212S-1WR3 (MORNSUN)
     
    UWF1215S-1WR3 (MORNSUN)