Серия Электромеханических реле TX2

Общие характеристики

Раздел Реле электромеханические
Тип контактов
Номинальное напряжение катушки
Тип тока катушки
Мощность катушки максимальная
Номинальный ток коммутации
Коммутируемое напряжение DC (макс)
Коммутируемое напряжение AC (пиковое)
Напряжение изоляции катушка-контакты
Рабочая температура
Размер 15×7.4×8.2 мм
Способ подключения выводов
Особенности
Применение

Документация на серию TX2

TESTING 2 A CAPACITY RELAY WITH HIGH SURGE VOLTAGE & HIGH BREAKDOWN VOLTAGE 15 .591 7.4 .291 8.2 .323 15 .591 7.4 .291 8.4 .331 mm inch TX RELAYS FEATURES • Breakdown voltage between contacts and coil: 2,000 V • Surge withstand between contacts and coil: 2,500 V • High contact capacity: 2 A 30 V DC • Surface-mount type available SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Rating Max. switching voltage Max. switching current Min. switching capacity ❇1 Nominal operating power Single side stable Expected life (min. operations) 2 A 30 V DC resistive Electrical (at 20 cpm) 1 A 30 V DC resistive 1 coil latching 2 coil latching Mechanical (at 180 cpm) 2 Form C 100 mΩ Gold-clad silver alloy 2 A 30 V DC 60 W 220 V DC 2A 10 µA 10 mV DC 140 mW (1.5 to 24 V DC) 270 mW (48 V DC) 100 mW (1.5 to 24 V DC) 200 mW (1.5 to 24 V DC) 108 105 5×105 Notes: ❇1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10 µA 1 mV DC – 10 mA 10 V DC]) ❇2The upper limit for the ambient temperature is the maximum temperature that can satisfy the coil temperature rise. Under the packing condition, allowable temperature range is from –40 to +70°C –40°C to +158°F. Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 2 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. 4 * Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 6 ms; detection time: 10 µs. *6 Half-wave pulse of sine wave: 6 ms. *7 Detection time: 10 µs. *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT. Initial insulation resistance*1 Between open contacts Initial breakdown Between contact sets voltage Between contact and coil Between open contacts Initial surge (10×160 µs) voltage Between contacts and coil (2×10 µs) Temperature rise*2 (at 20°C) Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1 min. (Detection current: 10 mA) 2,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 V (FCC Part 68) 2,500 V (Telcordia) Max. 50°C Max. 4 ms (Approx. 2 ms) Operate time [Set time]*3 (at 20°C) [Max. 4 ms (Approx. 2 ms)] Max. 4 ms (Approx. 1 ms) Release time [Reset time]*4 (at 20°C) [Max. 4 ms (Approx. 2 ms)] Min. 750 m/s2 {75 G} Functional*5 Shock resistance Destructive*6 Min. 1,000 m/s2 {100 G} 196 m/s2 {20 G}, 10 to 55 Hz Functional*7 at double amplitude of 3.3 mm Vibration resistance 294 m/s2 {30G}, 10 to 55 Hz Destructive at double amplitude of 5 mm –40°C to +85°C (up to 24 V coil) Conditions for operation, transport and Ambient tem- –40°F to +185°F (up to 24 V coil) perature ❇2 –40°C to +70°C (48 V coil) storage*8 (Not freezing and –40°F to +158°F (48 V coil) condensing at low Humidity 5 to 85% R.H. temperature) Unit weight Approx. 2 g .071 oz All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. PDF
Документация на TX2-L2-12V 

Дата модификации: 26.10.2005

Размер: 178.9 Кб

7 стр.

    Товары серии TX2

    Наименование i Упаковка
    TX2-L2-12V (PAN)
     
    Реле - Конфиг: 2C; Uкатушки: 12 В; AC-DC: DC; Pупр(max): 200 мВт; Iкомм: 2 А; UDC: 30 В в линейках 40 шт