Серия DC-DC модульных преобразователей TCL_DC

Общие характеристики

Раздел DC-DC модульные преобразователи
Монтаж
Количество каналов
Возможности
Комплекс защит короткого замыкания, перенапряжения
Уровень пульсаций
Напряжение изоляции вход-выход
Размер 100×75×27 мм
Рабочая температура

Документация на серию TCL_DC

Baar, 11. December 2014 Cleaning Guideline Scope This guideline covers hermetically sealed board mounted Traco converters. We do not recommend washing insert moulded products, where it is difficult to get them dry inside. Please check also, if there is an additional comment about washing in the datasheet or application note of the concerned product. Note: We do generally not recommend washing or cleaning electronic components. You should avoid it, if it is not absolutely necessary. It may reduce the reliability of the involved components in your application. Board cooling prior to cleaning process Converters and their associated application PCB assemblies should not be wash-cleaned after soldering until they had the opportunity to cool within the cleaning solution temperature. This will prevent vacuum absorption of the cleaning liquid into the module between the pins and the potting during cooling. Cleaning agents Cleaning method Classification Cleaning agents Water type Deionized water Ultrasonic wave Solvent type IPA Note: In general, the liquid temperature shall be less than 60°C. Cleaning process In aqueous cleaning, it is preferred to have an in-line cleaner system consisting of several cleaning stages (prewash, wash, rinse, final rinse, and drying). Deionised (DI) water is recommended for aqueous cleaning; the minimum resistively level is 1MΩ-cm. Tap-water quality varies per region in terms of hardness, chloride, and solid contents. Therefore, the use of tap water is not recommended for aqueous cleaning. Note: The total time of ultrasonic wave shall be less than 3 minutes. Drying After cleaning, assure that everything will be dry enough, that the moisture and other potential contaminants will not be present anymore. Use an air circulating chamber (e.g. 0.5-0.7m3/s) and thermal oven at 80-100°C (during 20-120min, depending on assembling, structure, components). Handheld air guns are not recommended. It is on customer’s own responsibility to ensure all components are dry. Product post-wash external appearance The marking or date-code may fade or disappear after cleaning. That does not concern the performance of the converter. Andreas Flühler, Head of Technical Services PDF
Рекомендации по промывке и сушке 

Cleaning Guideline

Дата модификации: 02.02.2021

Размер: 79 Кб

1 стр.

Документация на TCL 012-124 DC 

datasheet

Дата модификации: 25.11.2020

Размер: 315.2 Кб

3 стр.

Документация на серию TCL_DC 

datasheet

Дата модификации: 18.10.2013

Размер: 330.9 Кб

3 стр.

Документация на серию TCL_DC 

TCL-DC.indd

Дата модификации: 23.11.2005

Размер: 211.1 Кб

3 стр.

    Товары серии TCL_DC

    Наименование i Упаковка P вых U вх Выход U вх ном. U1 I1 КПД
    TCL 012-124 DC (TRACO) DC-DC модульный преобразователь - Монтаж: на DIN рейку; P вых: 24 Вт; #: 1; U вх: 9.5..... 1 шт
    TCL 024-105 DC (TRACO) в коробках 5 шт
    TCL 024-112 DC (TRACO) в коробках 5 шт
    TCL 024-124 DC (TRACO) в коробках 5 шт