Серия DC-DC модульных преобразователей TMR 3WIR

TRACO

Общие характеристики

Раздел DC-DC модульные преобразователи
Монтаж
Выходная мощность
Возможности
Комплекс защит
КПД
Напряжение изоляции вход-выход
Размер 21.8×9.6×11.2 мм
Рабочая температура

Документация на серию TMR 3WIR

Baar, 11. December 2014 Cleaning Guideline Scope This guideline covers hermetically sealed board mounted Traco converters. We do not recommend washing insert moulded products, where it is difficult to get them dry inside. Please check also, if there is an additional comment about washing in the datasheet or application note of the concerned product. Note: We do generally not recommend washing or cleaning electronic components. You should avoid it, if it is not absolutely necessary. It may reduce the reliability of the involved components in your application. Board cooling prior to cleaning process Converters and their associated application PCB assemblies should not be wash-cleaned after soldering until they had the opportunity to cool within the cleaning solution temperature. This will prevent vacuum absorption of the cleaning liquid into the module between the pins and the potting during cooling. Cleaning agents Cleaning method Classification Cleaning agents Water type Deionized water Ultrasonic wave Solvent type IPA Note: In general, the liquid temperature shall be less than 60°C. Cleaning process In aqueous cleaning, it is preferred to have an in-line cleaner system consisting of several cleaning stages (prewash, wash, rinse, final rinse, and drying). Deionised (DI) water is recommended for aqueous cleaning; the minimum resistively level is 1MΩ-cm. Tap-water quality varies per region in terms of hardness, chloride, and solid contents. Therefore, the use of tap water is not recommended for aqueous cleaning. Note: The total time of ultrasonic wave shall be less than 3 minutes. Drying After cleaning, assure that everything will be dry enough, that the moisture and other potential contaminants will not be present anymore. Use an air circulating chamber (e.g. 0.5-0.7m3/s) and thermal oven at 80-100°C (during 20-120min, depending on assembling, structure, components). Handheld air guns are not recommended. It is on customer’s own responsibility to ensure all components are dry. Product post-wash external appearance The marking or date-code may fade or disappear after cleaning. That does not concern the performance of the converter. Andreas Flühler, Head of Technical Services PDF
Рекомендации по промывке и сушке 

Cleaning Guideline

Дата модификации: 02.02.2021

Размер: 79 Кб

1 стр.

DC/DC Railway Converter • • • Compact SIP-8 metal case • • • I/O-isolation 3‘000 VDC • Short circuit protection and current limitation • • Remote On/Off TMR 3WIR Series, 3 Watt EN 50155 railway approval Ultra wide 4:1 Input: 9–36, 18–75 and 43–160 VDC Fully regulated outputs UL 62368-1 IEC 62368-1 Operating temperature range –40°C to +90°C 3-year product warranty The TMR 3WIR series is a set of 3 Watt DC/DC converters in a SIP-8 metal case. They operate up to 78°C environment temperature at full load and up to 90°C with a 50% load derating. With EN 50155 and UL 60950-1 certification, 3’000 VDC I/O-isolation voltage, external On/Off, current limitation and short circuit protection they cover a wide range of application when space is limited. The input of the converters is designed for a wide voltage range (4:1) and minimum load is not required. Models Order Code Input Voltage Range TMR 3-2410WIR TMR 3-2411WIR TMR 3-2419WIR TMR 3-2412WIR TMR 3-2413WIR TMR 3-2415WIR TMR 3-2421WIR TMR 3-2422WIR TMR 3-2423WIR TMR 3-4810WIR TMR 3-4811WIR TMR 3-4819WIR TMR 3-4812WIR TMR 3-4813WIR TMR 3-4815WIR TMR 3-4821WIR TMR 3-4822WIR TMR 3-4823WIR TMR 3-7210WIR TMR 3-7211WIR TMR 3-7219WIR TMR 3-7212WIR TMR 3-7213WIR TMR 3-7215WIR TMR 3-7221WIR TMR 3-7222WIR TMR 3-7223WIR www.tracopower.com 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) 43 - 160 VDC (110 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +5 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +5 VDC +12 VDC +15 VDC 700 mA 600 mA 333 mA 250 mA 200 mA 125 mA 300 mA 125 mA 100 mA 700 mA 600 mA 333 mA 250 mA 200 mA 125 mA 300 mA 125 mA 100 mA 700 mA 600 mA 333 mA 250 mA 200 mA 125 mA 300 mA 125 mA 100 mA April 27, 2020 Vnom Efficiency Imax –5 VDC –12 VDC –15 VDC 300 mA 125 mA 100 mA –5 VDC –12 VDC –15 VDC 300 mA 125 mA 100 mA –5 VDC –12 VDC –15 VDC 300 mA 125 mA 100 mA typ. 76 % 81 % 81 % 83 % 83 % 82 % 80 % 82 % 82 % 75 % 81 % 81 % 82 % 82 % 82 % 80 % 82 % 82 % 76 % 80 % 81 % 82 % 83 % 83 % 80 % 83 % 81 % Page 1 / 4 PDF
Документация на серию TMR 3WIR 

TMR 3WIR Datasheet 3 Watt DC/DC converter, railway, 4:1 input incl. 110 VDC nominal, regulated, 3000 VDC I/O-isolation, encapsulated, SIP-8 metal case

Дата модификации: 27.04.2020

Размер: 855.8 Кб

4 стр.

    Товары серии TMR 3WIR

    Наименование i Упаковка Каналов U вх Выход U вх ном. U1 I1 U2 I2
    TMR 3-2410WIR (TRACO)
     
    5 шт
    TMR 3-2411WIR (TRACO)
     
    5 шт
    TMR 3-2412WIR (TRACO)
     
    TMR 3-2413WIR (TRACO)
     
    5 шт
    TMR 3-2415WIR (TRACO)
     
    1 шт
    TMR 3-2419WIR (TRACO)
     
    TMR 3-2421WIR (TRACO)
     
    TMR 3-2422WIR (TRACO)
     
    TMR 3-2423WIR (TRACO)
     
    TMR 3-4810WIR (TRACO)
     
    9 шт
    TMR 3-4811WIR (TRACO)
     
    TMR 3-4812WIR (TRACO)
     
    TMR 3-4813WIR (TRACO)
     
    TMR 3-4815WIR (TRACO)
     
    TMR 3-4819WIR (TRACO)
     
    TMR 3-4821WIR (TRACO)
     
    TMR 3-4822WIR (TRACO)
     
    TMR 3-4823WIR (TRACO)
     
    TMR 3-7210WIR (TRACO)
     
    в линейках 10 шт
    TMR 3-7211WIR (TRACO)
     
    1 шт
    TMR 3-7212WIR (TRACO)
     
    TMR 3-7213WIR (TRACO)
     
    1 шт
    TMR 3-7215WIR (TRACO)
     
    1 шт
    TMR 3-7219WIR (TRACO)
     
    TMR 3-7221WIR (TRACO)
     
    TMR 3-7222WIR (TRACO)
     
    1 шт