G5V15VDC

Omron
G5V-1 Low Signal Relay Ultra-miniature, Highly Sensitive SPDT Relay for Signal Circuits • Ultra-miniature at 12.5 × 7.5 × 10 mm (L × W × H). • Wide switching power of 1 mA to 1 A. • High sensitivity: 150 mW nominal coil power consumption. • Fully-sealed construction offering environment resistance. • Conforms to FCC Part 68 requirements for coil to contacts. (1,500 V, 10 × 160 μs) RoHS Complia...
развернуть ▼ свернуть ▲
 

Аналоги 3

показать свернуть
Тип Наименование Корпус Упаковка i Конфиг Uкатушки AC-DC Pупр(max) Iкомм U dc U ac Изоляция T раб Монтаж Особенности Применение Примечания Тип колодки Магнитная система Семейство Карточка
товара
P= HFD23/005-1ZP (HONGFA)
 
в линейках 20 шт
P= HFD23/005-1ZS (HONGFA)
 
в линейках 20 шт Power/Signal Relay, 1 Form C, SPDT, Momentary, 0.03A (Coil), 7.5VDC (Coil), 150mW (Coil), 2A (Contact), 60VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
P= G5V15DC (OMRON)
 
в линейках 500 шт Реле - Конфиг: 1C; Uкатушки: 5 В; AC-DC: DC; Pупр(max): 150 мВт; Iкомм: 1 А; UDC: 24 В

Файлы 1

показать свернуть
G5V-1 Low Signal Relay Ultra-miniature, Highly Sensitive SPDT Relay for Signal Circuits • Ultra-miniature at 12.5 × 7.5 × 10 mm (L × W × H). • Wide switching power of 1 mA to 1 A. • High sensitivity: 150 mW nominal coil power consumption. • Fully-sealed construction offering environment resistance. • Conforms to FCC Part 68 requirements for coil to contacts. (1,500 V, 10 × 160 μs) RoHS Compliant ■Model Number Legend G 5 V-@ — ■Application Examples 1. Number of Poles/Contact Form 1: 1-pole/SPDT (1c) 1 • Telecommunication equipment • Audio-visual products ■Ordering Information Classification - Standard G 5 V 1 Enclosure Contact form Terminal Shape Model Rated coil voltage Minimun packing unit rating 3 VDC 5 VDC 6 VDC Fully SPDT PCB G5V-1 25 pcs/tube sealed (1c) terminals 9 VDC 12 VDC 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G5V-1 3 VDC Rated coil voltage 2. A special series of bifurcated crossbar contacts models are also available. ■Ratings ●Coil ●Contacts Rated voltage Rated current (mA) 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 50 30 25 16.7 12.5 6.25 Must operate Must release Max. voltage Coil Power voltage voltage (V) resistance consumption (V) (V) (Ω) (mW) % of rated voltage 60 167 240 200% at Approx. 150 80% max. 10% min. 23°C 540 960 3,840 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Load Resistive load Item Contact type Single crossbar Contact Au-alloy + Ag material 0.5 A at 125 VAC; Rated load 1 A at 24 VDC Rated carry 2A current Max. switching 125 VAC, 60 VDC voltage Max. switching 1A current ■Characteristics Contact resistance *1 Operate time Release time Insulation resistance *2 Dielectric strength Vibration resistance Shock resistance Durability Between coil and contacts Between contacts of the same polarity Destruction Malfunction Destruction Malfunction Mechanical Electrical Failure rate (P level) (reference value) *3 Ambient operating temperature Ambient operating humidity Weight 100 mΩ max. 5 ms max. 5 ms max. 1,000 MΩ min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same polarity.) 1,000 VAC, 50/60 Hz for 1 min 400 VAC, 50/60 Hz for 1 min 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 1,000 m/s2 100 m/s2 5,000,000 operations min. (at 36,000 operations/hr) 100,000 operations min. (under rated load, at 1,800 operations/hr) 1 mA at 5 VDC -40°C to 70°C (with no icing or condensation) 5% to 85% Approx. 2 g Note: The values here are initial values. *1. Measured with 10 mA at 1 VDC with a voltage drop method. *2. Measured with a 500 VDC megohmmeter between coil and contacts and a 250 VDC megohmmeter between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength. *3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 100 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. 1 PDF
Документация на G5V15VDC 

G5V-1

Дата модификации: 23.07.2012

Размер: 687.9 Кб

4 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.