TD301DCAN

Industrial Bus TD5(3)01DCAN Series Single universal CAN isolation transceiver module FEATURES RoHS  Integrated high efficiency isolated DC/DC converter  Two-port isolation (3kVDC)  High baud rate up to 1Mbps  Operating ambient temperature range: -40℃ to +105℃  Complies with ISO 11898 standard  An unpowered node does not disturb the bus lines  The bus supports maximum 110 ...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Корпус DIP-8 DIP7
Кол-во каналов передачи данных
Диапазон питающих напряжений
Диапазон рабочих температур
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 2

показать свернуть
Industrial Bus TD5(3)01DCAN Series Single universal CAN isolation transceiver module FEATURES RoHS  Integrated high efficiency isolated DC/DC converter  Two-port isolation (3kVDC)  High baud rate up to 1Mbps  Operating ambient temperature range: -40℃ to +105℃  Complies with ISO 11898 standard  An unpowered node does not disturb the bus lines  The bus supports maximum 110 nodes  Set isolation and ESD bus protection in one EN62368-1 The TD301DCAN/ TD501DCAN series’ main function is to convert TTL / CMOS level into isolated CAN bus differential level signals. The use of IC integrated technology allows for power isolation, signal isolation, CAN transceiver and bus protection all in one single CAN bus transceiver module, which withstands an isolation test voltage of 3000VDC. Also, they can easily be embedded in the user’s end equipment, to achieve fully functional CAN bus network connectivity. Selection Guide Part No. Power input (VDC) Baud Rate (bps) Static Current (mA) Maximum Operating Current(mA) Bus Maximum Voltage(VDC) Number of Nodes EN TD301DCAN 3.3 5k-1M 50 90 ±36 110 -- TD501DCAN 5 5k-1M 35 80 ±36 110 Certification Absolute Limits Item Input Surge Voltage (1sec.max.) Pin Soldering Temperature Operating Conditions Min. Typ. Max. 3.3V series -0.7 -- 5 5V series -0.7 -- 7 -- -- 300 ℃ Min. Typ. Max. Unit 3.15 3.3 3.45 0.7VCC -- VCC+0.5 Soldering spot 1.5mm away from case, 10s max. Unit VDC 3.3V Series input Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC High-level VIH Low-level VIL 0 -- 0.8 High-level VOH VCC-0.4 VCC-0.2 -- Low-level VOL -- 0.2 0.4 TXD Drive Current IT 2 -- -- RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +3.3V Min. Typ. Max. VDC mA 5V Series Input Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC High-level VIH Low-level VIL High-level VOH Low-level 4.75 5 5.25 0.7VCC -- VCC+0.5 0 -- 0.8 VCC-0.4 VCC-0.2 -- VOL -- 0.2 0.4 TXD Drive Current IT 2 -- -- RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +5V 2021.06.11-A/8 Unit VDC mA Page 1 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на TD301DCAN 

TDx01DCAN Keywords:

Дата модификации: 28.12.2021

Размер: 1.38 Мб

5 стр.

Industrial Bus TD5(3)01DCAN Series Single universal CAN isolation transceiver module FEATURES  Integrated high efficiency isolated DC/DC converter  Two-port isolation (3kVDC)  High baud rate up to 1Mbps  Operating ambient temperature range: -40℃ to +105℃  Complies with ISO 11898 standard  An unpowered node does not disturb the bus lines  The bus supports maximum 110 nodes  Set isolation and ESD bus protection in one RoHS EN62368-1 The TD301DCAN/ TD501DCAN series’ main function is to convert TTL / CMOS level into isolated CAN bus differential level signals. The use of IC integrated technology allows for power isolation, signal isolation, CAN transceiver and bus protection all in one single CAN bus transceiver module, which withstands an isolation test voltage of 3000VDC. Also, they can easily be embedded in the user’s end equipment, to achieve fully functional CAN bus network connectivity. Selection Guide Part No. Power input (VDC) Baud Rate (bps) Static Current (mA) Maximum Operating Current(mA) Bus Maximum Voltage(VDC) Number of Nodes EN TD301DCAN 3.3 5k-1M 50 90 ±36 110 -- TD501DCAN 5 5k-1M 35 80 ±36 110 Certification Absolute Limits Item Input Surge Voltage (1sec.max.) Pin Soldering Temperature Operating Conditions Min. Typ. Max. 3.3V series -0.7 -- 5 5V series -0.7 -- 7 -- -- 300 ℃ Max. Unit Soldering spot 1.5mm away from case, 10s max. Unit VDC 3.3V Series input Specifications Item Symbol Min. Typ. Power Supply Input Voltage VCC 3.15 TXD Logic Level RXD Logic Level 3.3 3.45 High-level VIH 0.7VCC -- VCC+0.5 Low-level VIL 0 -- 0.8 High-level VOH VCC-0.4 VCC-0.2 -- Low-level VOL -- 0.2 0.4 TXD Drive Current IT 2 -- -- RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +3.3V Min. Typ. Max. VDC mA 5V Series Input Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC High-level VIH Low-level VIL High-level VOH Low-level 4.75 5 5.25 0.7VCC -- VCC+0.5 0 -- 0.8 VCC-0.4 VCC-0.2 -- VOL -- 0.2 0.4 TXD Drive Current IT 2 -- -- RXD Output Current IR -- -- 10 2021.06.11-A/8 Unit VDC mA Page 1 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на TD301DCAN 

Subject:

Дата модификации: 23.06.2021

Размер: 1.4 Мб

5 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.