TD301DCANH3

Industrial Bus TD5(3)01DCANH3 Series Single high rate CAN isolation transceiver module FEATURES  Integrated high efficiency isolated DC/DC converter  Two-port isolation (3.0kVDC)  High baud rate up to 1Mbps  Operating ambient temperature range: -40℃ ~ +105℃  Complies with ISO 11898 standard  An unpowered node does not disturb the bus lines  The bus supports maximum 110 node...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Корпус DIP-8 PDIP8
Кол-во каналов передачи данных
Диапазон питающих напряжений
Диапазон рабочих температур
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
Industrial Bus TD5(3)01DCANH3 Series Single high rate CAN isolation transceiver module FEATURES  Integrated high efficiency isolated DC/DC converter  Two-port isolation (3.0kVDC)  High baud rate up to 1Mbps  Operating ambient temperature range: -40℃ ~ +105℃  Complies with ISO 11898 standard  An unpowered node does not disturb the bus lines  The bus supports maximum 110 nodes  Set isolation and ESD bus protection in one  EN60950 approval RoHS The TD301DCANH3/ TD501DCANH3 series’ main function is to convert TTL / CMOS level into isolated CAN bus differential level signals. The use of IC integrated technology allows for power isolation, signal isolation, CAN transceiver and bus protection all in one single CAN bus transceiver module, which withstands an isolation test voltage of 3000VDC. Also, they can easily be embedded in the user’s end equipment, to achieve fully functional CAN bus network connectivity. Selection Guide Part No. Power input (VDC) Baud rate (bps) Static Current (mA) Maximum Operating Current (mA) Bus Maximum Voltage (VDC) Number of Nodes TD301DCANH3 3.3 20k-1M 35 90 ±58 110 TD501DCANH3 5 20k-1M 30 80 ±58 110 Certification CE Absolute Limits Item Input Surge Voltage (1sec.max.) Pin Soldering Temperature Operating Conditions Min. Typ. Max. 3.3V series -0.7 -- 5 5.0V series -0.7 -- 7 -- -- 300 ℃ Min. Typ. Max. Unit 3.15 3.3 3.45 0.7VCC -- VCC+0.5 Soldering spot 1.5mm away from case, 10s max. Unit VDC 3.3V Series nput Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC High-level VIH Low-level VIL 0 -- 0.8 High-level VOH VCC-0.4 VCC-0.2 -- Low-level VOL -- 0.2 0.4 TXD Drive Current IT -- -- 2 RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +3.3V Min. Typ. Max. VDC mA 5.0V Series Input Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC High-level VIH Low-level VIL High-level VOH Low-level 4.75 5 5.25 0.7VCC -- VCC+0.5 0 -- 0.8 VCC-0.4 VCC-0.2 -- VOL -- 0.2 0.4 TXD Drive Current IT -- -- 2 RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +5.0V 2018.12.18-A/4 Unit VDC mA Page 1 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на TD301DCANH3 

Subject:

Дата модификации: 07.01.2019

Размер: 829.4 Кб

4 стр.

    Публикации 1

    показать свернуть
    10 апреля 2020
    новость

    Изолированные интерфейсные модули RS-485 и CAN производства Mornsun

    Компания Mornsun выпускает широкий ассортимент интерфейсных микросхем и полнофункциональных изолированных интерфейсных модулей RS–485/232 и CAN для популярных промышленных интерфейсов. Особенности: напряжение изоляции «вход–выход»... ...читать

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.