Industrial Bus TD5(3)01DCANHE Series Surge protected CAN isolation transceiver module FEATURES  Two-terminal isolation(2.5kVDC)  High baud rate of up to 1 Mbps  Operating ambient temperature range: -40℃ to +85℃  The bus supports maximum 110 nodes  ESD: Contact ±8kV/Air±15kV  Surge protection: ±4kV RoHS EN62368-1 The TD301DCANHEH/ TD501DCANHE series’ main function is to conver...
развернуть ▼ свернуть ▲
 

Технические характеристики

показать свернуть
Корпус DIP-8
Кол-во каналов передачи данных
Диапазон питающих напряжений
Диапазон рабочих температур
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
Industrial Bus TD5(3)01DCANHE Series Surge protected CAN isolation transceiver module FEATURES  Two-terminal isolation(2.5kVDC)  High baud rate of up to 1 Mbps  Operating ambient temperature range: -40℃ to +85℃  The bus supports maximum 110 nodes  ESD: Contact ±8kV/Air±15kV  Surge protection: ±4kV RoHS EN62368-1 The TD301DCANHEH/ TD501DCANHE series’ main function is to convert TTL / CMOS level into isolated CAN bus differential level signals. The use of IC integrated technology allows for power isolation, signal isolation, CAN transceiver and bus protection all in one single CAN bus transceiver module, which withstands an isolation test voltage of 3000VDC. The internal components are highly integrated, with low electromagnetic radiation and high immunity to electromagnetic interference, which improve the capablity of surge protection and simplify the application circuits. Also, they can easily be embedded in the user’s end equipment, to achieve fully functional CAN bus network connectivity. Selection Guide Part No. Power input (VDC) Baud rate (bps) Static Current (mA) Maximum Operating Current (mA) Number of Nodes TD301DCANHE 3.3 20k-1M 25 90 110 TD501DCANHE 5 20k-1M 20 75 110 Certification EN Absolute Limits Item Input Surge Voltage (1sec.max.) Pin Soldering Temperature Operating Conditions Min. Typ. Max. 3.3V series -0.7 -- 5 5.0V series -0.7 -- 7 -- -- 300 ℃ Min. Typ. Max. Unit Soldering spot 1.5mm away from case, 10s max. Unit VDC 3.3V Input Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC 3.15 3.3 3.45 High-level VIH 0.7VCC -- VCC+0.5 Low-level VIL 0 -- 0.8 High-level VOH VCC-0.4 VCC-0.2 -- Low-level VOL -- 0.2 0.4 TXD Drive Current IT 2 -- -- RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +3.3V Min. Typ. Max. VDC mA 5.0V Input Specifications Item Symbol Power Supply Input Voltage TXD Logic Level RXD Logic Level VCC 4.75 5 5.25 High-level VIH 0.7VCC -- VCC+0.5 Low-level VIL 0 -- 0.8 High-level VOH VCC-0.4 VCC-0.2 -- Low-level VOL -- 0.2 0.4 TXD Drive Current IT 2 -- -- RXD Output Current IR -- -- 10 Serial Interface Standard CAN controller interface for +5.0V 2021.08.31-A/4 Unit VDC mA Page 1 of 4 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation PDF
Документация на TD301DCANHE 

Subject:

Дата модификации: 17.09.2021

Размер: 1.01 Мб

4 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.