DRT-960-24 PBF

D R T- 9 6 0 960W Three Phase Industrial DIN RAIL Power Supply series Features : Three-Phase AC 340 ~ 550V wide range input High efficiency 91% and low dissipation Protections: Short circuit / Overload / Over voltage / Over temperature Optional parallel function(1+1) Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved EN610...
развернуть ▼ свернуть ▲
 
 

Технические характеристики

показать свернуть
Примечание AC-DC Regulated Power Supply Module
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
D R T- 9 6 0 960W Three Phase Industrial DIN RAIL Power Supply series Features : Three-Phase AC 340 ~ 550V wide range input High efficiency 91% and low dissipation Protections: Short circuit / Overload / Over voltage / Over temperature Optional parallel function(1+1) Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test 3 years warranty R SPECIFICATION MODEL OUTPUT INPUT DRT-960-24 DRT-960-48 DC VOLTAGE 24V 48V RATED CURRENT 40A 20A CURRENT RANGE 0 ~ 40A 0 ~ 20A RATED POWER 960W 960W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p VOLTAGE ADJ. RANGE 48 ~ 55V 1.0% 24 ~ 28V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION 0.5% LOAD REGULATION 0.5% 0.5% 0.5% SETUP, RISE TIME 200ms, 60ms/400VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 14ms/400VAC 30ms/500VAC at full load Three-Phase 340 ~ 550VAC (Dual phase operation possible in connecting L1,L3,FG Note.5) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 91% AC CURRENT (Typ.) INRUSH CURRENT (max.) 2A/400VAC 1.6A/500VAC COLD START 50A LEAKAGE CURRENT 200ms, 60ms/500VAC at full load 92% <3.5mA / 530VAC 105 ~ 125% rated output power OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) 5 (TSW2) Detect on heatsink of power diode Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B MTBF DIMENSION PACKING NOTE Protection type : Shut down o/p voltage, re-power on to recover 110 5 (TSW1) Detect on heatsink of power transistor 85 ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY OTHERS Protection type : Constant current limiting, unit will shut down o/p voltage after 3 sec. , re-power on to recover 30 ~ 36V 59 ~ 66V Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A 122.5Khrs min. MIL-HDBK-217F (25 ) 276*125.2*100mm (W*H*D) 3.3Kg; 4pcs/14.2Kg/1.14CUFT 1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Dual phase operation(connecting L1,L3,FG)is allowed under certain derating to output load. Please refer to the derating curves for details. File Name:DRT-960-SPEC 2007-01-12 PDF
Документация на серию DRT-960 

DRT-960.cdr

Дата модификации: 13.02.2007

Размер: 287.3 Кб

3 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.