PB-360N-48

Зарядные устройства
развернуть ▼ свернуть ▲
 
 

Технические характеристики

показать свернуть
Выходная мощность (ном)
Выход
Напряжение 1 канала
Выходной ток 1 канала
Тип стабилизации
Вход
Конструктивное исполнение
Примечание AC-DC Regulated Power Supply Module
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 2

показать свернуть
PB-360 360W Single Output Battery Charger series ■ Features : Charger for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese) (Note.1) 3 stage charging AC 115/230VAC selected by switch Built-in passive PFC function compliance to BS EN/EN61000-3-2 Class A (option) Protection: Short circuit / Reverse polarity / Over voltage / Over temperature 2 color LED loading indicator Low cost, High reliability FAN on/off control(Depends on charging current) 3 years warranty (except for 48V) UL62368-1 PB 360 P TPTC004 IEC60335-1,-2-29 (P type only) 12 12:14.4V 24:28.8V 48:57.6V P:With Passive PFC N:Without Passive PFC SPECIFICATION PB-360□-12 MODEL OUTPUT PB-360□-24 BOOST CHARGE VOLTAGE Vboost 14.4V 28.8V 57.6V FLOAT CHARGE VOLTAGE Vfloat 13.6V 27.2V 54.4V VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V 26 ~ 28.8V 52 ~ 58.6V 40 ~ 125Ah 20 ~ 65Ah RECOMMENDED BATTERY CAPACITY(AMP HOURS) Note 6 BATTERY TYPE 80 ~ 240Ah Open & Sealed Lead Acid OUTPUT CURRENT (Typ.) Note 7 24.3A INPUT PROTECTION 90 ~ 132VAC / 180 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 7A/115VAC 3.5A/230VAC COLD START 60A 6.25A 127 ~ 187VDC / 254 ~ 370VDC 86% 87% LEAKAGE CURRENT <3.5mA / 240VAC SHORT CIRCUIT O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on REVERSE POLARITY By internal fuse OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE (Note 5) EMC EMISSION 16 ~ 18V 31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work 59 ~ 64V Short: Stop Charging -20 ~ +60℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH non-condensing ±0.05%/℃ (0 ~ 45℃) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB approved by TUV(except for 48V), UL62368-1, CSA C22.2 No. 62368-1 , EAC TP TC 004 approved, Design refer to BS EN/EN62368-1 for P type only I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3 (only P type), EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, criteria A, EAC TP TC 020 MTBF DIMENSION 115.8Khrs min. PACKING NOTE 12.5A VOLTAGE RANGE OVER TEMPERATURE FUNCTION REMOTE CONTROL (CN5) OTHERS PB-360□-48 MIL-HDBK-217F (25℃) 253*135*48.5mm(L*W*H) 1.5Kg; 6pcs/10Kg/1.03CUFT 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 7. Maximum charging current will be in the range of 90~110% rated output current. 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:PB-360-SPEC 2021-06-01 PDF
Документация на PB-360N-48 

PB-360-20210601.cdr

Дата модификации: 17.08.2021

Размер: 75.8 Кб

2 стр.

PB-360 360W Single Output Battery Charger series Features : 3 stage charging AC 115/230VAC selected by switch Built-in passive PFC function compliance to EN61000-3-2 Class A (option) Protection: Reverse Polarity / Short circuit / Over voltage / Over temperature Charger for lead-acid batteries 2 color LED loading indicator Low cost, High reliability FAN on/off control(Depends on charging current) 2 years warranty (except for 48V) PB 300/360 P (P type only) 12 1.300W without FAN 2.360W with FAN 12:14.4V 24:28.8V 48:57.6V P:With Passive PFC N:Without Passive PFC SPECIFICATION MODEL PB-360 PB-360 -12 PROTECTION -48 14.4V 28.8V 57.6V FLOAT CHARGE VOLTAGE 13.6V 27.2V 54.4V 26 ~ 28.8V 26 ~ 58.6V 40 ~ 125Ah 20 ~ 65Ah 12.5A 6.25A RECOMMENDED BATTERY CAPACITY(AMP HOURS)(Note 5) INPUT PB-360 BOOST CHARGE VOLTAGE VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V OUTPUT -24 80 ~ 200Ah BATTERY TYPE Open & Sealed Lead Acid OUTPUT CURRENT 24.3A VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 85% POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 7A/115VAC 3.5A/230VAC COLD START 60A LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 90 ~ 110% rated output current Protection type : Constant current limiting, recovers automatically after fault condition is removed REVERSE POLARITY By internal fuse OVER VOLTAGE OVER TEMPERATURE FUNCTION REMOTE CONTROL (CN5) WORKING TEMP. 86% 16 ~ 18V 31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work 87% 59 ~ 64V Short: Stop Charging -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 45 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB Approved by TUV(except for 48V), UL60950-1 Approved SAFETY STANDARDS SAFETY & EMC (Note 4) WITHSTAND VOLTAGE MTBF DIMENSION PACKING NOTE I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY OTHERS I/P-O/P:3KVAC ISOLATION RESISTANCE Compliance to EN61000-3-2,-3 (only P type) Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 115.8Khrs min. MIL-HDBK-217F (25 ) 253*135*48.5mm(L*W*H) 1.5Kg; 6pcs/10Kg/0.95CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. File Name:PB-360-SPEC 2007-03-05 PDF
Документация на серию PB-360 

PB-360.cdr

Дата модификации: 23.03.2007

Размер: 287.7 Кб

2 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.