DR-120-48 PBF

120W Single Output Industrial DIN RAIL Power Supply DR-120 series ■ Features : AC input range selectable by switch Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching freque...
развернуть ▼ свернуть ▲
 
 

Технические характеристики

показать свернуть
Выходная мощность (ном)
Напряжение 1 канала
Выходной ток 1 канала
Тип стабилизации
Типы защиты THERMAL; SHORT CIRCUIT; OVERLOAD; OVER VOLTAGE
Количество выходов
Входное напряжение AC
КПД
Рабочая температура
Примечание AC-DC Regulated Power Supply Module, 1 Output, 120W, Hybrid
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 2

показать свернуть
120W Single Output Industrial DIN RAIL Power Supply DR-120 series ■ Features : AC input range selectable by switch Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 55KHz 3 years warranty Bauar t gepruft Sicherheit egel ma ge od o s be wac g SPECIFICATION MODEL OUTPUT INPUT DR-120-12 DR-120-24 DR-120-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A RATED POWER 120W 120W 120W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p VOLTAGE ADJ. RANGE 12 ~ 14V VOLTAGE TOLERANCE Note.3 ±2.0% 24 ~ 28V ±1.0% 48 ~ 53V ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% LOAD REGULATION ±1.0% ±1.0% ±1.0% SETUP, RISE TIME 500ms, 70ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 36ms/230VAC 32ms/115VAC at full load 88 ~ 132VAC/176 ~ 264VAC by switch 248 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.6A/115VAC LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE www. tuv.com ID 2000000000 500ms, 70ms/115VAC at full load 84% 85% 1.6A/230VAC COLD START 20A/115VAC 40A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 29 ~ 33V 58 ~ 65V 15 ~ 16.5V Protection type : Shut down o/p voltage, re-power on to recover 90℃±5℃(TSW1) 90℃±5℃(TSW1) 85℃±5℃ (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55011,EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 432.1Khrs min. MIL-HDBK-217F (25℃) 65.5*125.2*100mm (W*H*D) 0.79Kg; 20pcs/16.5Kg/1.29CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:DR-120-SPEC 2018-01-12 PDF
Документация на DR-120-24 

DR-120-20180112.cdr

Дата модификации: 09.01.2018

Размер: 82.8 Кб

2 стр.

120W Single Output Industrial DIN RAIL Power Supply DR-120 series Features : AC input range selectable by switch Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 55KHz 3 years warranty SPECIFICATION MODEL OUTPUT INPUT DR-120-12 DR-120-24 DR-120-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A RATED POWER 120W 120W 120W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p VOLTAGE ADJ. RANGE 24 ~ 28V 1.0% 48 ~ 53V 1.0% 12 ~ 14V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 70ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 36ms/230VAC 32ms/115VAC at full load 88 ~ 132VAC/176 ~ 264VAC by switch 248 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.6A/115VAC LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 500ms, 70ms/115VAC at full load 84% 85% 1.6A/230VAC COLD START 20A/115VAC 40A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 29 ~ 33V 58 ~ 65V 15 ~ 16.5V Protection type : Shut down o/p voltage, re-power on to recover 90 5 (TSW1) 90 5 (TSW1) 85 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 136.8Khrs min. MIL-HDBK-217F (25 65.5*125.2*100mm (W*H*D) 0.79Kg; 20pcs/16.5Kg/1.29CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:DR-120-SPEC 2011-06-17 PDF
Документация на серию DR-120 

DR-120.cdr

Дата модификации: 24.08.2011

Размер: 329.5 Кб

2 стр.