DR-4512 PBF

45W Single Output Industrial DIN Rail Power Supply DR-45 series Features : Universal AC input/Full range Protections:Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 100KHz 3 years warra...
развернуть ▼ свернуть ▲
 
 

Технические характеристики

показать свернуть
Выходная мощность (ном)
Напряжение 1 канала
Количество выходов
Входное напряжение AC
Рабочая температура
Примечание AC-DC Regulated Power Supply Module, 1 Output, 42W, Hybrid
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
45W Single Output Industrial DIN Rail Power Supply DR-45 series Features : Universal AC input/Full range Protections:Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 100KHz 3 years warranty R SPECIFICATION MODEL DR-4505 DR-4512 DR-4515 DR-4524 DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 5A 3.5A 2.8A 2A CURRENT RANGE 0 ~ 5A 0 ~3. 5A 0 ~ 2.8A 0 ~ 2A RATED POWER 25W 42W 42W 48W 200mVp-p 240mVp-p 480mVp-p 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT INPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 800ms, 60ms/230VAC at full load HOLD TIME (Typ.) 100ms/230VAC at full load VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 0.75A/230VAC COLD START 28A/115VAC 56A/230VAC OVER LOAD Shut down o/p voltage, re-power on to recover Tj 135 typically (U1) Detect on heat sink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +50 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL508, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A MTBF 364.6K hrs min. MIL-HDBK-217F (25 93*78*67mm (L*W*H) 0.31Kg; 48pcs/16.1Kg/1.3CUFT DIMENSION PACKING NOTE 80% <1mA / 240VAC TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE OTHERS 77% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY (Note 4) 77% LEAKAGE CURRENT OVER TEMPERATURE EMC 120 ~ 370VDC EFFICIENCY (Typ.) PROTECTION OVER VOLTAGE SAFETY & 4.75 ~ 5.5V ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:DR-45-SPEC 2005-10-20 PDF
Документация на серию DR-45 

DR-45.cdr

Дата модификации: 24.10.2005

Размер: 265 Кб

2 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.