SP-150-15 PBF

SP-150 150W Single Output with PFC Function series Features : Universal AC input / full range Built-in active PFC function, PF>0.93 Protections:Short circuit/Over load/Over voltage/Over temperature Built-in constant current limiting circuit Remote ON-OFF control(Optional) LED indicator for power on 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warra...
развернуть ▼ свернуть ▲
 
 

Технические характеристики

показать свернуть
Выходная мощность (ном)
Напряжение 1 канала
Выходной ток 1 канала
Типы защиты THERMAL; OVER LOAD; OVER VOLTAGE; SHORT CIRCUIT
Количество выходов
Входное напряжение AC
КПД
Рабочая температура
Примечание AC-DC Power Factor Correction Module, 1 Output, 150W, Hybrid
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 1

показать свернуть
SP-150 150W Single Output with PFC Function series Features : Universal AC input / full range Built-in active PFC function, PF>0.93 Protections:Short circuit/Over load/Over voltage/Over temperature Built-in constant current limiting circuit Remote ON-OFF control(Optional) LED indicator for power on 100% full load burn-in test Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty R SPECIFICATION MODEL SP-150-3.3 SP-150-5 SP-150-7.5 SP-150-12 SP-150-13.5 SP-150-15 SP-150-24 SP-150-27 SP-150-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 30A 30A 20A 12.5A 11.2A 10A 6.3A 5.6A 3.2A CURRENT RANGE 0 ~ 30A 0 ~ 30A 0 ~ 20A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A 0 ~ 6.3A 0 ~ 5.6A 0 ~ 3.2A RATED POWER 99W 150W 150W 150W 151.2W 150W 150W 151.2W 153.6W 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT 3.14 ~ 3.63V 4.75 ~ 5.5V VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 600ms, 30ms at full load SETUP, RISE TIME 20ms at full load HOLD TIME (Typ.) VOLTAGE RANGE INPUT Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 67% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC 1.2A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVER LOAD 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.63 ~ 4.46V 5.5 ~ 6.75V 8.25 ~ 10.13V 13.2 ~ 16.2V 14.85 ~ 18.2V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V PROTECTION OVER VOLTAGE FUNCTION 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V PF>0.98/115VAC at full load 75% 79% 80% 80% SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE UL60950-1, TUV EN60950-1 and S-MARK J60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC NOTE 84% , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF OTHERS 84% Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +85 (Note 4) 83% 95 5 (TSW1 : Detect on heatsink of power transistor) OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down REMOTE CONTROL(OPTION) CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION EMC 81% DIMENSION Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 191.2K hrs min. MIL-HDBK-217F (25 ) 199*99*50mm (L*W*H) PACKING 0.76Kg; 20pcs/16.4Kg/1.28CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:SP-150-SPEC 2005-09-13 PDF
Документация на серию SP-150 

SP-150.cdr

Дата модификации: 25.10.2005

Размер: 337.4 Кб

2 стр.