TS-400 400W True Sine Wave DC-AC Power Inverter series Features : True sine wave output (THD<3%) High surge power up to 800W High efficiency up to 88.5% Thermostatically controlled cooling fan Built-in remote ON-OFF control Front panel indicator for operation status Power ON-OFF switch Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input reverse polarity / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 2 years warranty E13 SPECIFICATION MODEL 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) Factory setting set at 110VAC Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W 60 0.1Hz 50 0.1Hz WAVEFORM True sine wave (THD<3%) at rated input voltage typ. 50/60Hz selectable by setting button 50/60Hz selectable by setting button 3.0%, at rated input voltage FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal BAT. VOLTAGE 12V 24V 48V 12V 24V 48V VOLTAGE RANGE (Typ.) DC CURRENT (Typ.) 10.5 ~ 15VDC 40A 21 ~ 30VDC 20A 42 ~ 60VDC 10A 10.5 ~ 15VDC 40A 21 ~ 30VDC 20A 42 ~ 60VDC 10A 0.63A 0.32A 1.25A 0.63A 0.32A 87% 86% 87.5% 88.5% NO LOAD CURRENT DRAW typ. 1.25A EFFICIENCY (Typ.) 1mA 86% Open & sealed Lead Acid Note.1 84.5% FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN BAT. POLARITY OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) GFCI PROCTECTION FUNCTION REMOTE CONTROL 40A*2 11.3 4% 40A*1 22.5 4% 20A*1 45 4% 40A*2 11.3 4% 40A*1 22.5 4% 20A*1 45 4% 10.5 4% 21 4% 42 4% 10.5 4% 21 4% 42 4% 85 75 By internal fuse open 85 5 75 5 5 5 70 5 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover Optional (Only type F) Open : Normal work ; Short : Remote off STORAGE TEMP., HUMIDITY VIBRATION -30 ~ +70 None @ 50% load o / -22 ~ +158 F, 10 ~ 95% RH 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes None Design refer to UL458 None Bat I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Bat I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION&RADIATION Compliance to FCC class A None EMS IMMUNITY DIMENSION PACKING 5 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. -10 ~ +40 @ 100% load ; +60 20% ~ 90% RH non-condensing LVD SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE 70 Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor WORKING TEMP. WORKING HUMIDITY SAFETY STANDARDS NOTE TS-400-248 FREQUENCY BATTERY TYPES OTHERS TS-400-224 100 / 110 / 115 / 120VAC selectable by setting button S.W OFF MODE CURRENT DRAW ENVIRONMENT TS-400-212 MAXIMUM OUTPUT POWER AC REGULATION INPUT TS-400-148 400W AC VOLTAGE OUTPUT TS-400-124 TS-400-112 RATED POWER / 70% RH Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,8 ENV50204 205*158*67mm (L*W*H) 1.73Kg; 6pcs/11.4Kg/1.55CUFT 1.Efficiency is tested by 300W, linear load at 12V/24V/48V input voltage. 2.All parameters not specified above are measured at rated load, 25 of ambient temperature. File Name:TS-400-SPEC 2009-07-22 PDF
Документация на серию TS-400 

TS-400.cdr

Дата модификации: 10.09.2009

Размер: 360.6 Кб

2 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.