DRP-240-48 PBF

240W Single Output Industrial DIN RAIL Power Supply DRP-240 series ■ Features : Universal AC input / Full range Built in active PFC function Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in t...
развернуть ▼ свернуть ▲
 
 

Технические характеристики

показать свернуть
Выходная мощность (ном)
Напряжение 1 канала
Количество выходов
Входное напряжение AC
Рабочая температура
Примечание AC-DC Power Factor Correction Module, 1 Output, 240W, Hybrid
Нашли ошибку? Выделите её курсором и нажмите CTRL + ENTER

Файлы 2

показать свернуть
240W Single Output Industrial DIN RAIL Power Supply DRP-240 series ■ Features : Universal AC input / Full range Built in active PFC function Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION MODEL OUTPUT DRP-240-24 DRP-240-48 DC VOLTAGE 24V 48V RATED CURRENT 10A 5A CURRENT RANGE 0 ~ 10A 0 ~ 5A RATED POWER 240W 240W RIPPLE & NOISE (max.) Note.2 80mVp-p 150mVp-p VOLTAGE ADJ. RANGE 48 ~ 53V ±1.0% 24 ~ 28V VOLTAGE TOLERANCE Note.3 ±1.0% LINE REGULATION ±0.5% LOAD REGULATION ±1.0% SETUP, RISE TIME 800ms, 40ms/230VAC 24ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT Note.5 85 ~ 264VAC ±0.5% ±1.0% 800ms, 40ms/115VAC at full load 24ms/115VAC at full load 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) EFFICIENCY (Typ.) 0.96/230VAC 84% 0.99/115VAC at full load AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.8A/115VAC 1.4A/230VAC LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE 85% COLD START 27A/115VAC 45A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 54 ~ 60V 30 ~ 36V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -10 ~ +70℃ (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION 20 ~ 90% RH non-condensing SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION UL508, UL60950-1, TUV EN60950-1 approved OTHERS ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55011,EN55032 (CISPR32) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 289.9Khrs min. MIL-HDBK-217F (25℃) 125.5*125.2*100mm (W*H*D) 1.2Kg; 12pcs/15.5Kg/1.29CUFT DIMENSION PACKING NOTE -20 ~ +85℃, 10 ~ 95% RH 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:DRP-240-SPEC 2017-07-07 PDF
Документация на DRP-240-48 

DRP-240-20170707.cdr

Дата модификации: 04.07.2017

Размер: 80.4 Кб

2 стр.

240W Single Output Industrial DIN RAIL Power Supply DRP-240 series Features : Universal AC input / Full range Built in active PFC function Protections:Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 100KHz 3 years warranty R SPECIFICATION MODEL OUTPUT DRP-240-24 DRP-240-48 DC VOLTAGE 24V 48V RATED CURRENT 10A 5A CURRENT RANGE 0 ~ 10A 0 ~ 5A RATED POWER 240W 240W RIPPLE & NOISE (max.) Note.2 80mVp-p 150mVp-p VOLTAGE ADJ. RANGE 48 ~ 53V 1.0% 24 ~ 28V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION 0.5% LOAD REGULATION 1.0% 24ms/230VAC HOLD TIME (Typ.) INPUT 1.0% 800ms, 40ms/230VAC SETUP, RISE TIME VOLTAGE RANGE 0.5% Note.5 85 ~ 264VAC 800ms, 40ms/115VAC at full load 24ms/115VAC at full load 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) EFFICIENCY (Typ.) 0.96/230VAC 84% 0.99/115VAC at full load AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.8A/115VAC 1.4A/230VAC LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE 85% COLD START 27A/115VAC 45A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 54 ~ 60V 30 ~ 36V Protection type : Shut down o/p voltage, re-power on to recover 100 5 (TSW1)Detect on heat sink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -10 ~ +70 WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE -20 ~ +85 (Refer to output load derating curve) , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL508, UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE EMC (Note 4) I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A 105.5Khrs min. MIL-HDBK-217F (25 125.5*125.2*100mm (W*H*D) 1.2Kg; 12pcs/15.5Kg/1.2CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:DRP-240-SPEC 2005-06-20 PDF
Документация на серию DRP-240 

DRP-240.cdr

Дата модификации: 08.07.2005

Размер: 339.8 Кб

2 стр.

    Внимание! Точность указанного на сайте описания товара не может быть гарантирована. Для получения более полной и точной информации о товаре смотрите техническое описание (Datasheet) на сайте производителя.